SY120SA Series Operating Manual
© 2004 by SYRIS Technology Corp.
7
2.8
System & password setting function
[need to be in the login status]
2.8.1
Configure Master card password (
needs to be in the login status
)
1.
Follow the sequence of [FUN] [4] [1] (nnnn) (nnnn) [EN]
(nnnn)(nnnn):new password need enter 2 times to confirm
* system default value is 1234.
2.8.2
Usage of Master card (Maximum 3 Master cards)
1. Follow the sequence of [FUN][4][2](K)(D)[EN], if correct and response normal ststus and see
(K)to decide back to original ststus or waiting setting card response.
2. If K = 1 and enter proximity card modeand waiting setting card response.Correct response
back to correct status and original status.
(K):K = 1 use to set card;K = 0 use to cancel card
(D):Set or cancel setting card number, Range:1~3
* if use any setting card(1-3) , the other card password need to operate with setting card
password.
2.8.3
Settup anti-duress password
1. Enter[FUN][4][3](N)(pppp)[EN]
(N): anti-duress group, Range:1~4
(pppp): enter anti-duress password
* System default value is 1~4 units, all is 5555. If personal passowrd is the same as anti-duress
password. (It can be personal password.)
2.8.4
Enabled or Disable anti-duress
1. Enter[FUN][4][4](E)[EN]
(E):E = 1 enabled anti-duress alarm;
E = 0 cancel anti-duress (default)
2.8.5
Enabled or Disable Door Forced
(V2.8)
1. Enter[FUN][4][5](E)[EN]
(E):E = 1 enabled door forced alarm;
E = 0 cancel door forced (default)
2.8.6
Enabled or Disable Door Time-Out
(V2.9)
1. Enter[FUN][4][6](E) (TT) [EN]
(E):E = 1 enabled door time-out alarm;
E = 0 cancel door time-out (default)
(TT): Time-Out time setting, Range:01~99; default :20,unit:sec
2.8.7
Enabled or Disable Encryption Card
(V3.0)
1. Enter[FUN][4][8](E) [EN]
(E):E = 1 enabled Encryption Card Mode(Use SYRIS Encryption Card);
E = 0 cancel Encryption Card Mode (default)