SY120SA Series Operating Manual
© 2004 by SYRIS Technology Corp.
11
2.12.5 Holiday
Setting
1. Enter[FUN][8][5](HH)(MMDD)[EN]
(HH): Holiday number, Range 01~30, Insert 00 to clean all holidaysetting.
(MMDD): holiday number date; MM = month, DD = day
2.13 Configure system communication ID code
[needs to be in the login status]
1. Enter[FUN][9][1](NNN)[EN]
(NNN):SY120SA Controller ID, Range 001~999; default :001
2.14 Notice:
1. While change Master card’s password, one needs to change 3 cards at same time. if one uses
Master card to login then system will make it (it
Æ
Access with Master card’s passwrod) as
invalid.
2. SY120SA controller(system) and reader needs to be connected the GND. Please use parallel
cable while using parallel cable with 0.75mm shield cover cable, it can connect up to 100
meter long. While useing normal phone line the distance limits is within 20 meters.
3. The voltage output limits is 5A current. If one needs higher electric current, then please add
another relay.
4. Relay output can only accept up to 1A current. if one needs to increase the limits, then please
add another relay.