HYDROBOX
™
Operations And Maintenance Manual
INSTALLATION 2-6
©
2006 SyQwest Incorporated
2.2.5
- Installing the HydroBox Electronics
Instructions are provided in this section regarding the physical installation of the HydroBox Sensor Unit
and the PC that is used for the User Interface. Guidelines are provided for locating and/or mounting the
HydroBox Sensor unit and the PC. The installer should refer to Section 2.2.7 for information on electrical
hookup.
Selecting a Location for the Electronics
The HydroBox Sensor Unit is designed for portable, marine applications but maybe used in permanent
installations as well. The user must determine if the HydroBox Sensor Unit is to be mounted on the
vessel or just placed in a convenient place on-board the vessel. Either way the appropriate location for
the unit needs to be determined. The following considerations should be investigated before deciding
upon a location:
1. User Supplied Personal Computer
The first step in the equipment location process is to determine the optimum place for viewing the data.
The unit should be positioned to provide the optimum viewing angle and within easy reach of the operator
whenever possible. This will vary depending on the size of the vessel and type of Personal Computer
(Desktop or Laptop) but is most important to insure the comfort and success of the user. The location
selection should consider that standard PC displays are not easily readable in direct sunlight. Adequate
space for the computer and any peripherals that need to be connected should be considered as well.
Finally, provisions need to be made to properly secure the equipment for the worst sea conditions that
may be encountered.
2. Cable Lengths.
Both the Data Interface Cable and the DC Power Cable supplied with the product are 10 feet long. Thus,
the Sensor Unit must be installed within 10 feet of both the user supplied Personal Computer and a 10-
30VDC Power Source. The unit must also provide adequate access for cabling termination without
binding, and allow suitable space for servicing the equipment. (If necessary, the data cable may be
extended beyond 10 feet. See Section 2.2.7 for more information)
3. Water Resistance.
The Sensor Unit has passed the EN60529 IP65 Water Resistance Standard which ensures that the unit is
completely sealed and is Splash Proof. The unit should NOT however be installed in an area where the
unit may be submerged in water.
4. Environmental.
The operating temperature of the HydroBox Sensor is –25C to +60C thus the operating temperature range
of the PC is likely the limiting factor for temperature. The unit has also passed all of the EN60945
emission tests (radiation and immunity). For optimum system performance it is still recommended that
the installer mount or place the Sensor unit in an area that is at least several feet away from any other
electronic equipment or machinery on the vessel. The unit should also be mounted or placed in an area
that won’t be exposed to water if practical.