HYDROBOX
™
Operations and Maintenance Manual
INTRODUCTION 1-7
©
2006 SyQwest Incorporated
Directivity Index
The directivity index measures the ability of a transducer to reject noise from extraneous sources. In the
ocean, noise may be coming from all directions, but a narrow beam transducer will only “hear” noise
within the beam width pattern. A sonar systems signal to noise ratio (SNR) will be affected by the ability
of a transducer to reject unwanted noise, and thus is related to the directivity index. The higher the
directivity index of a transducer, the better the ability to reject unwanted noise.
1.4
Specifications
1.4.1
HydroBox Sensor Specifications
Units
Feet or Meters
Depth Ranges
0-15, 30, 60, 120, 240, 450, 900, 1500, 2400 Feet.
0-5, 10, 20, 40, 80, 150, 300, 500, 800 Meters. Auto-ranging Modes in all units.
Data Offset
0 to 30 feet (0 to10 meters)
Shift Range
1 foot increments in depths to 100 feet
10 foot increments in depths greater than 100 feet
Zoom Range
15, 30, 60, 120, 240, 480 feet; 5, 10, 20, 40, 80 , 160 meters
Zoom Modes
Bottom Zoom, Bottom Lock, Marker Zoom, GUI Zoom (Playback Only)
Display
Normal Data, Zoom Data, Navigation, Depth, Command/Status, Color Control for Data: 4
Selections or Custom (User Input), Data Color Invert possible
Sound Velocity
4600 - 5250 ft/sec (1400 - 1600 mt/sec) 1 mt/sec int.
Depth Resolution
0.1 foot, 0.01 meters. (in less than 100 meters) ,
0.1 meters for depths greater than 100 meters
Depth Accuracy
Meets or exceeds all current IHO hydrographic requirements for single beam echo
sounders; 0-40m 2.5cm, 40-200m 5.0cm, >200m 10.0cm
Data Output
NMEA 0183, DPT, DBT, PMC, Hypack & HydroPro Compatible
Geographic Position
NMEA 0183, GLL, GGA, RMC, VTG, VHW, HDT
Selectable Baud Rates (RS-232): 4800, 9600, 19200, 38400
Data Interface
SYQWEST HydroBox Interface, 57600 Baud (RS-422)
Printer Output
Centronics (Parallel Port) interface to TDU Series Thermal Printers
Shallow Water
Operation
< 1 meter; frequency dependant
Transmit Rate
Up to 10 Hz, depth and operator mode dependant
Event Marks
Periodic, External, and/or Manual (Periodic selectable in 1 minute intervals)
Data File Output
Stores Depth, Navigation, and Graphic Data in ODC format (Proprietary)
Normal and Zoom Data stored is Pixel data and can be played back and/or printed
Data File Playback
Files can be played back and/or printed at Normal or Fast-Forward speed, with Pause and
GUI Zoom available
Frequency Output
Selectable at time of purchase from any of the following:
200Khz, 50Khz or 33Khz (single channel system) or
50/200Khz, 33/200Khz dual frequency system
( impedance matched transducers available from SyQwest)
Transmit Power
600 Watts (nominal) matched to transducer (1000 Watts capable)
Input Power
10-30 Volts DC, Nominal power 8 Watts,
Reverse Polarity and Over Voltage Protected
Dimensions
25.4 cm (10”) Length, 15.876 cm (6.25”) Width, and 6.25 cm (2.5”) Height
Weight
0.9 kg (2.0 lbs)
Environmental
-25°C to +60°C Operating Temperature (-55°C to +90°C Storage)
Water Resistant to EN60529 IP65
EMC meets EN60945 Emissions; CE Compliant