FACTORY DEFAULTS
The factory default values are stored in ROM and are loaded into the active
configuration at power up or by the ATZ command. In addition, the designated
default profile is subsequently loaded, and may change some of the factory default
values. The designated default profile can be changed by entering the &Y
command where n is one of the two possible user profiles.
The defaults shown are those used by Conexant in factory profiles zero and one.
These may be overwritten by the OEM with ConfigurACE prior to placing the
firmware in PROM. Minimum and maximum values may also be imposed by
ConfigurACE in response to country PTT requirements.
The default values shown in Table A-14 may vary by modem firmware
configuration.
Consult the MCU firmware release notes for exact configuration.
The factory default values may be loaded at any time by entering the &Fn
command.
Table A-14. S-Parameter Summary
Register
Function
Range
Units
Saved
Default**
S0
Rings to Auto-Answer
0-255
rings
*
0
S1
Ring Counter
0-255
rings
0
S2
Escape Character
0-255
ASCII
*
43
S3
Carriage Return
Character
0-127
ASCII
13
S4
Line Feed Character
0-127
ASCII
10
S5
Backspace Character
0-255
ASCII
8
S6
Wait Time before Blind
Dialing or for Dial Tone
2-255
s
*
2
S7
Wait Time for Carrier,
Silence, or Dial Tone
1-255
s
*
50
S8
Pause Time for Dial
Delay Modifier
2-255
s
*
2
S9
Carrier Detect Response
Time
1-255
0.1 s
*
6
S10
Lost Carrier To Hang Up
Delay
1-255
0.1 s
*
14
S11
DTMF Tone Duration
50-255
0.001 s
*
95
S12
Escape Prompt Delay
(EPD)
0-255
0.02 s
*
50
S14
General Bit Mapped
Options Status
-
-
138 (8Ah)
S16
Test Mode Bit Mapped
Options Status
-
-
0
S19
Reserved
-
-
0
S20
Reserved
-
-
0
Содержание SM9234D
Страница 1: ...SM9256D and SM9234D Modems User s Guide 0049 2500 001 Rev B ...
Страница 5: ...Page v local or long distance transmission charges ...
Страница 6: ......
Страница 14: ......
Страница 17: ...Introduction Page 17 ...
Страница 18: ......
Страница 26: ......
Страница 28: ...Using the Modem s Auto Connect Feature Page 28 ...
Страница 84: ...AT Commands Page 84 ATS86 025 500ms after no carrier a dial tone is heard on the local handset ...
Страница 87: ...AT Commands Page 87 example modem models supporting V92 may not support K56 ...
Страница 107: ...AT Commands Page 107 Data Transfer Bit error rates for each direction ...
Страница 136: ...AT Commands Page 136 S86 26 Remote hangup detected ...
Страница 198: ...AT Commands Page 198 OK ERROR If not in Voice Mode ...
Страница 213: ...AT Commands Page 213 ...
Страница 214: ......