Synway Information Engineering Co., Ltd
SMG-C Series Analog Gateway User Manual (Version 1.7.1)
Page 55
Register Port
Sets whether to register the port to the SIP server.
When this item is set to
No
, the item
Reg Status
on the FXS settings interface
Unregistered
; when this item is set to
Yes
, the item
Reg Status
shows
Failed
or
Registered
.
SIP Account
When the port initiates a call to SIP, this item corresponds to the username of SIP.
The default SIP account is 80XX among which XX represents the corresponding
port number. For example, the default SIP account corresponding to Port 1 is 8001,
and that corresponding to Port 8 is 8008.
Display Name
Set the content of the displayname field of the SIP message. If it doesn’t set with
any value, the displayname field will by default display the content of callerid.
Password
Registration password of the port. To register a port to the SIP server, both items
SIP Account
and
Password
must be filled in.
Authentication
Username
Authentication username of a port, used to register the port to the SIP server when
IMS network is enabled.
Note: This item appears only when IMS Network or Multi-Registrar Server is
enabled.
Display Name
Preferred
In case this feature is enabled and the port group or the whole gateway is
registered, if the display name set by the port are different from that set by the port
group, the displayname in the sent SIP message will be the one set by the port. In
case this feature is disabled, if the port group is registered, the displayname in the
sent SIP message will be the display name set by the port group; if the whole
gateway is registered, the displayname in the sent SIP message will be the
displayname of the gateway.
Server Index
The index of the SIP server which will be quoted by the current FXS port.
Auto Dial Number,
Wait Time before
Auto Dial
The FXS port will dial the
Auto Dial Number
if there is no dialing operation after
pickup within a designated time period (i.e.
Wait Time before Auto Dial
).
Input Gain, Output
Gain
Adjusts the gain of the voice input to/ output from the FXS port. Range of value:
-24~12, calculated by dB, with the default value of 0.
Echo Canceller
The echo cancellation feature for a call conversation over the FXS channel. By
default, this feature is enabled and the effect can reach 128ms.
Forbid Outgoing
Call
If this feature is enabled, the FXS port will be forbidden to call out. The default
setting is
disabled
.
CID
CallerID. If this feature is enabled, the FXS port will send the CallerID of the
incoming IP call together with the ringing tone to the corresponding station. The
default setting is
enabled
. CallerID displays digits only and will filter out any other
characters if exist.
Call Waiting
If this feature is enabled, the FXS port in conversation can accept another call from
IP and keep it in the waiting state. Once the current conversation is finished and the
station hangs up, the call in the waiting state will ring the station and wait for
answer. The default setting is
disabled
.
DND
Do Not Disturb. If this feature is enabled, the FXS port will reply the 403 message to
reject all incoming calls. The default setting is
disabled
.