technical reference
3
16
Synrad
Pulstar p100
operator’s manual
User I/O connections
Figure 3-10 illustrates the input circuit’s equivalent internal schematic while Table 3-5 provides Pulstar
p100 input circuit specifications.
USER I/O INPUT SIGNAL PINS
PWM INPUT (+)
(9)
PWM RETURN (–)
(1)
REMOTE RESET/START REQUEST
(2)
REMOTE INTERLOCK
(3)
SHUTTER OPEN REQUEST
(10)
INPUT COMMON
(11)
600 Ohm, 2W
600 Ohm, 2W
600 Ohm, 2W
PULSTAR p100
INPUT CIRCUITRY
220 Ohm, 1/8W
430 Ohm, 1/10W
Figure 3-10
Input equivalent schematic
Table 3-5
Input circuit specifications
Input Signal Name
Input Device Type and Specifications
PWM Input
High-speed optoisolator LED, forward voltage drop (Vf) 1.5 VDC
Off state Vmax +0.8 VDC
On state Vmin +3.5 VDC @ 3 mA
On state (continuous) Vmax +6.7 VDC @ 10 mA
Frequency, max. 100 kHz
Remote Reset/Start Request
Bi-directional optoisolator LED, forward voltage drop (Vf) 1.15 VDC
Remote Interlock
Off state Vmax < 1.0 VDC
Shutter Open Request
On state Vmin ±5.0 VDC @ 7 mA
On state (continuous) Vmax ±24.0 VDC @ 40 mA
Note:
The
Remote Reset/Start Request
input must not be sent until Pulstar’s +5 VDC power supply
has stabilized (approximately 200 ms after DC power-up).
Содержание Pulstar P100 Series
Страница 2: ......
Страница 4: ......
Страница 12: ...x Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 48: ...operation 210 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 78: ...technical reference 330 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 102: ...maintenance troubleshooting 424 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 110: ...index i8 Synrad Pulstar p100 operator s manual This page intentionally left blank...