Chiller preparation guidelines
■
You must provide fittings to adapt the laser’s 1/2-inch O.D. polyethylene cooling tubing to the chiller’s
Inlet and Outlet ports. These fittings can be either “quick disconnect” or compression type fittings.
■
Because Pulstar’s cooling tubing is supplied in inch sizes, do not use metric tubing fittings unless you
have installed the appropriate inch-to-metric tubing adaptors. The use of metric fittings on inch size
tubing will lead to coolant leaks or may allow the pressurized tubing to blow off the fitting.
Coolants
SYNRAD recommends that the laser’s cooling fluid contain at least 90% distilled water by volume. In
closed-loop systems, use a corrosion inhibitor/algaecide such as Optishield
®
Plus or equivalent as required.
Avoid glycol-based additives because they reduce the coolant’s heat capacity and high concentrations may
affect power stability. For SYNRAD lasers, the minimum coolant setpoint is 18 °C (64 °F) so glycol is not
necessary unless the chiller is subjected to freezing temperatures. If tap water is used, chloride levels should
not exceed a concentration of 25 parts per million (PPM) and total hardness should be below 100 PPM.
Install a filter on the chiller’s return line and inspect frequently. Pulstar p100 lasers incorporate the follow-
ing wetted materials in the coolant path—nickel-plated brass, copper, Delrin
®
, nitrile, and stainless steel.
Note:
DO NOT use de-ionized (DI) water as a coolant. DI water is unusually corrosive and is not rec-
ommended for mixed material cooling systems.
Setting coolant temperature
Choosing the correct coolant temperature is important to the proper operation and longevity of your laser.
When coolant temperature is lower than the dew point (the temperature at which moisture condenses out
of the surrounding air), condensation forms inside the laser housing leading to failure of laser electronics as
well as damage to optical surfaces.
The greatest risk of condensation damage occurs when the laser is in a high heat/high humidity environ-
ment and the chiller’s coolant temperature is colder than the dew point of the surrounding air or when the
system is shut down, but coolant continues to flow through the laser for extended periods of time.
The chiller’s temperature setpoint must always be set above the dew point temperature. In cases where this
is not possible within the specified coolant temperature range of 18 °C to 22 °C (64 °F to 72 °F), then the
following steps MUST be taken to reduce the risk of condensation damage.
■
Use the
Gas Purge
port to introduce nitrogen or dry, filtered air into the laser housing.
■
Air-condition the room or the enclosure containing the laser.
■
Install a dehumidifier to reduce the humidity of the enclosure containing the laser.
■
Stop coolant flow when the laser is shut down.
■
Increase coolant flow by an additional 3.8 lpm (1.0 GPM). Do not exceed a coolant pressure of 414
kPa (60 PSI).
■
Refer to Table 1-2 and gradually increase coolant temperature until it is above the dew point tempera-
ture and condensation disappears. Do not exceed a coolant temperature of 30 °C (86 °F).
Note:
Pulstar OEM p100 lasers can be operated at coolant temperatures up to 30 °C to reduce problems
associated with condensation; however, this may result in decreased laser performance and/or
reduced laser lifetime.
Содержание Pulstar P100 Series
Страница 2: ......
Страница 4: ......
Страница 12: ...x Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 48: ...operation 210 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 78: ...technical reference 330 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 102: ...maintenance troubleshooting 424 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 110: ...index i8 Synrad Pulstar p100 operator s manual This page intentionally left blank...