maintenance/
troubleshooting
4
11
Synrad
Pulstar p100
operator’s manual
Troubleshooting
Status LEDs
Pulstar p100 LED indicators, also mirrored as output signals on the
User I/O
connector, provide status
information to the user. Table 4-2 shows Pulstar output signal and LED indicator states during normal and
fault conditions.
User I/O
outputs are Closed when the state indicated by the signal name is logically True.
Table 4-2
Status signals
LED
LED Status
Output Signal Name
User I/O Output Status
Normal
Fault
Normal
Fault
INT
Green
– –
Interlock Open
Open
– –
– –
Red
Interlock Open
– –
Closed
TMP
Green
– –
Fault Detected
Open
– –
– –
Red
Fault Detected
– –
Closed
RDY
Yellow
– –
Laser Ready
Closed
– –
– –
Off/Flashing
Laser Ready
– –
Open
SHT
Blue
– –
Shutter Open
Closed
– –
– –
Off
Shutter Open
– –
Open
– –
Flashing
Fault Detected
– –
Closed
LASE
Red
– –
Laser Active
Closed
– –
– –
Off
Laser Active
– –
Open
On DC power-up of an OEM p100 laser, the
RDY
lamp illuminates yellow when
INT
and
TMP
indicators
illuminate green. The
SHT
LED illuminates blue when a
Shutter Open Request
signal is applied. When
both
RDY
and
SHT
indicators are lit, the RF driver is enabled and internal tickle is applied. Once the RF
driver is enabled, the application of a PWM Command signal causes the
LASE
indicator to illuminate red
as lasing begins.
Note:
Pulstar p100
RDY
and
SHT
LEDs denote separate control functions. Although the
RDY
lamp
may light while the
SHT
LED is Off (
Shutter Open Request
signal missing), no power is applied
to the RF driver until both
RDY
and
SHT
indicators are illuminated.
Содержание Pulstar P100 Series
Страница 2: ......
Страница 4: ......
Страница 12: ...x Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 48: ...operation 210 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 78: ...technical reference 330 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 102: ...maintenance troubleshooting 424 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Страница 110: ...index i8 Synrad Pulstar p100 operator s manual This page intentionally left blank...