20
After the unit has been lit please test all integral gas carrying joints and components
for gas soundness using relevant gauges.
If the problem persists, please contact Active Food Systems.
4.4 Changing a MicroGas Controller:
Changing a MicroGas controller should be attempted if you: switch the front Green
Rocker Switch on but it does not initiate the appliances fan to start up – if the front
panel is not down at the time please wait up to 20 seconds before you can hear the
fan noise.
Remove the grill top panel to access the screws holding the panel in place (Figure
1).
Remove the MicroGas controller by disconnecting all wires and harnesses, and
loosening the two screws securing the controller (Figure 4). Before swapping out
the whole MicroGas controller, firstly perform a continuity test to make sure it is not
just the 20x5 4A fuse that has blown.
Figure 4
The replacement MicroGas controller can be fitted in the reverse order the faulty
controller was removed.
If the problem persists, please contact Active Food Systems.
Содержание SG1300
Страница 1: ...1 Synergy Grill 900 User Engineer Installation Conversion Guide...
Страница 15: ...15 Synergy Grill 900 User Engineer Servicing Cleaning Guide...
Страница 23: ...23 6 Wiring Diagram...
Страница 28: ...28...