Synergy SG1300 Скачать руководство пользователя страница 19

 

19 

 

The ignitor can be removed by loosening the screw seen in Figure 2. 
 
 
The replacement ignitor can be replaced and secured in the same way the faulty one 
was removed.  
If the reported problem persists, please contact Active Food Systems. 
 

 

4.3 Changing a Valve: 

You should only have to change a valve if you switch on your appliance and there is 
no  ignition  sequence  and  the  red  front  panel  light  illuminates  after  roughly  15 
seconds.  If the ignition sequence begins (the ignitor sparks) but no flame appears 
from the burner and then the red light comes on after the unit has attempted this 
three times you must check: the gas supply has not dropped coming from the Outlet 
Port on the internal Gas Valve (2.2 C & D), nothing is blocking the Burner or the Gas 
is connected properly. 

Remove the grill top panel to access the screws holing the panel in place (Figure 1). 

Please make sure the internal valve switch is ON.  If the valve is OFF, please switch 
ON  and  try  turning  the  unit  on  again.    If  the  grill  now  lights  you  do  not  need  to 
change the valve. 

 
 
 

 

 

Figure 3 

Remove the valve by loosening the In, Out, and Injector pipe nuts and the two screws 
behind the valve bracket (Figure 3).  Once these have been undone please remove 
the  faulty  Gas  Valve  and  insert  the  replacement  valve,  reversing  the  above  steps 
until all fixings are gas tight. 
 

Содержание SG1300

Страница 1: ...1 Synergy Grill 900 User Engineer Installation Conversion Guide...

Страница 2: ...ation Section 1 5 Gas Supply Section 1 6 Electrical Supply Section 1 7 Water Supply Section 1 8 Starting up and Shutting Down Section 2 1 Testing and Purging Section 2 2 Checking Pressures Section 2 3...

Страница 3: ...3 Section 3 3 1 Changing Injectors for Natural Gas Section 3 3 2 Reinstating the Internal Gas Valve Regulator for Natural Gas Section 3 3 3 Nat Gas Data Plate...

Страница 4: ...gas valves This appliance is CE marked declaring the compliance with EC directives The Gas Types and Pressures for the destined country are stated on the appliance Data Plate The instructions through...

Страница 5: ...ht oil such as vegetable oil can smooth out the pitting and stop any food from sticking Fresh unoiled cast iron cooking bars are also prone to rust if you do not season them from the start First week...

Страница 6: ...our warranty registration and return to Active Food Systems to start your warranty This unit is heavy do not attempt to lift with less than four people 1 2 Technical Information Gas Type Width Depth N...

Страница 7: ...nput kW 11 4 11 0 11 0 12 6 Total nominal rate m3 h 1 206 1 32 1 28 0 994 kg h Nominal NET heat Input kW burner 5 7 5 7 5 7 6 3 Nominal Rate burner m3 h 0 603 0 69 0 65 0 497 kg h Burner pressure mbar...

Страница 8: ...access to the Synergy Grill This can be blocked by tea towels trays or anything thin enough to store under the unit 1 4 Ventilation The unit must be installed in a draught free position Adequate vent...

Страница 9: ...to the appliance to allow a fast shut off during an emergency or routine servicing 1 6 Electrical Supply This unit is supplied via a 5A 3 pin plug at 240v This unit must be earthed or the appliance w...

Страница 10: ...mated ignition system via the Front Switches Each Front Green Rocker Switch is assigned in order of each burner Left Switch controls the Left Burner and so forth Pressing this switch will cause the ap...

Страница 11: ...wing so when the gas valve opens the manometer will increase again SO if you have 1 0mbar of fan pressure already showing and the Gas Valve opens and you then increase the final pressure to 15 0 mbar...

Страница 12: ...tural Gas 2 2mm jet using a 9mm socket and keep in a safe place in case you need to convert back to Natural Gas and replace with 1 5mm Jet Screw down the burner again A new Gasket may be required 3 1...

Страница 13: ...re as possible If the outlet pressure point has a significant drop in pressure from the inlet please go through step 3 1 2 again 3 3 Converting to Natural Gas Natural Gas Jets 2 2mm should have been k...

Страница 14: ...Screw and keep safe for when you need to convert back C Connect your manometer to the Outlet Pressure Post Follow steps 2 2 C D and set burner to 15mbar D Replace the Brass Regulator Cover Screw Nat...

Страница 15: ...15 Synergy Grill 900 User Engineer Servicing Cleaning Guide...

Страница 16: ...ing 22 Spares List 23 24 Section 7 Installation Tips and Advice for Gas Installation Engineer 25 Section 4 1 Flame Dropping Out Through Service Section 4 2 Changing an Ignitor Section 4 3 Changing a V...

Страница 17: ...se book your engineer in for an AM service before the unit is switched on for greater ease of work If the appliance must be worked on whilst it is still hot always use heat protective gloves when hand...

Страница 18: ...off causing the system to lock out The detection system will send a False Signal back to the Microgas Controller if the electrode is contaminated with salts fats and oils To stop this simple problem w...

Страница 19: ...he unit has attempted this three times you must check the gas supply has not dropped coming from the Outlet Port on the internal Gas Valve 2 2 C D nothing is blocking the Burner or the Gas is connecte...

Страница 20: ...at the time please wait up to 20 seconds before you can hear the fan noise Remove the grill top panel to access the screws holding the panel in place Figure 1 Remove the MicroGas controller by disconn...

Страница 21: ...d screw into the metal fan tray 4 6 Burner Injector Cleaning Burners and Jets require periodic cleaning to ensure all ports and apertures are free from debris and blockages Failure to periodically cle...

Страница 22: ...ront Red Fault Light on Yes No Check the Air Pressure Switch Is it blocked with grease Remove the air hose from the brass air nipple and blow with your mouth it should click with pressure Internal gas...

Страница 23: ...23 6 Wiring Diagram...

Страница 24: ...from around the burner and the flame sensor igniter 3 Use a piece of abrasive strip to remove the salts and oils from the white ceramic of the flame sensor and metal electrode as per the picture 4 Wi...

Страница 25: ...l Replacement Ceramic Kit SG630 CERAMIC900 Synergy Grill Replacement Ceramic Kit SG900 CERAMIC1300 Synergy Grill Replacement Ceramic Kit SG1300 C4065 C6065 Synergy Grill Honeywell Air Pressure Switch...

Страница 26: ...l Ceramic Cap SG90 CF Synergy Grill Ceramic Ring TRANSFORMER Synergy Grill Transformer 36J41K 200 Synergy Grill Gas valve 630CONVERSIONKIT Synergy Grill Conversion Natural LPG Kit SG630 900CONVERSIONK...

Страница 27: ...y ceramic block is open and you can see the smaller hole in the metalwork behind the ceramic Ensure the Ceramic Ring is orientated correctly the three nodules should be at the bottom of the ring and t...

Страница 28: ...28...