17
Important Information
All internal servicing work on this appliance is to be done via the front panel and by
a certified engineer. Please make sure access to the front panel and directly under
the grill is always kept clear.
Please ensure the Gas Isolating Valve and Electrical Supply has been switched off
before any service work is carried out.
We recommend the appliance is cold before work is started. If possible, please book
your engineer in for an AM service before the unit is switched on for greater ease of
work. If the appliance must be worked on whilst it is still hot always use heat
protective gloves when handling hot parts on and below the cooking surface.
General Tools Required:
2.5mm Allen Key
(Gas Pressure post)
3mm Allen Key
(Ignitor)
5mm Allen Key
(Fan)
Flat Headed Screwdriver (Brass Regulator Cover Screw & Plastic
Regulator Adjustment Screw)
Pozi 2 Screwdriver
(General Screws Throughout)
Socket Set – 7 & 9mm
(Burner Bolts & Jets)
Adjustable Spanner
(internal Gas Valve Removal)
Manometer
(Gas Pressures)
Wire Brush
(Burner and Ignitor Cleaning)