4 Servicing Your Synergy Grill:
4.1 Flame Dropping Out Throughout Service:
If you have noticed the appliance Burner Flame has started dropping out during
service, and has been getting worse over time, you need to make sure the Flame
Detector on the unit is free from debris.
This appliance relies on Flame Rectification to determine whether the Burner Flame
is lit or not. The internal MicroGas controller senses the required electrical circuit is
completed via the ions in the Burner Flame completing the circuit - this completed
circuit keeps the Internal Gas Valve open and the gas flowing. If no signal is received
the gas will shut off causing the system to lock out. The detection system will send
a False Signal back to the Microgas Controller if the electrode is contaminated with
salts, fats and oils.
To stop this simple problem, we recommend a Daily Cleaning Regime of removing
the Cast Iron Cap and Ceramic Ring from around the burner and using a damp (not
wet) cloth to remove any build-up, no matter how small, of salts and oils from the
White Ceramic of the igniter/flame sensor. The please put back the Cap and Ring
and continue onto vacuuming the larger ceramics.
If you are still having problems with the Burner Flame dropping out during service
after you have thoroughly cleaned the Flame Detector please contact Active Food
Systems.
4.2 Changing an Ignitor:
Remove the grill top panel to access the screws holding the panel in place (Figure
1).
Figure 1.
Figure 2.