2.2 Checking Pressures: 

A)

 

To gain access to the internal gas valve please remove the top collar from 
the unit and place to one side, you should now have access to four screws 
securing the front panel to the unit. Remove these four screws and place 
the front panel underneath the appliance being careful not to pull on any 
front panel wires. 

 

B)

 

Unscrew the Inlet Pressure Post with a 2.5mm Allen key and connect your 
manometer to make sure the supply pressure is consistent with your gas 
type.  Once happy with the pressure, remove your manometer and tighten 
up the Inlet Pressure Post. 

C)

 

Unscrew  the  Outlet  Pressure  Post  with  a  2.5mm  Allen  key  and  connect 
your manometer.  

D)

 

Turn on the unit, making sure any packaging is free from the burner, and 
adjust the valve until gas pressure reads 15mbar. 
YOU  MUST  ZERO  YOU  MANOMETER  ONCE  THE  UNIT  IS  RUNNING

When the appliance starts up, the fan pressure in the system will cause 
the manometer to increase by around 0.7 to 1.0 mbar before any gas starts 
flowing, so when the gas valve opens the manometer will increase again.  
SO, if you have 1.0mbar of fan pressure already showing and the Gas Valve 
opens  and  you  then  increase  the  final  pressure  to  15.0  mbar  you  only 
actually have 14.0mbar of gas pressure; the unit will run cold.  To correctly 
adjust  the  pressure,  turn  the  grill  on,  let  it  ignite  with  a  steady  flame. 
Turn OFF the GAS VALVE (not the Grill) using the switch on the Valve 
(the  unit  should  then  start  attempting  to  reignite)  and  zero  your 
manometer  so  its  reads  ZERO  and  then  turn  the  Gas  Valve  back  on

.  

The pressure displaying now on your manometer is only the Gas Pressure

not the Air and Gas.  Changing of pressure is achieved by removing the 
Brass Regulator Cover Screw and adjust/screw the white lug inside – anti 
clockwise  lowers  pressure,  clockwise  increases  it.    Once  outlet  pressure 
has  been  reached,  retighten  the  Brass  Regulator  Cover  Screw,  remove 
manometer and retighten the Outlet Pressure Post. 

Once  the  gas  pressure  has  been  set  the  flame  length  should  be  a  steady  10mm 
around the burner, if the flame is different please make sure the Gas Jet & Gas Types 
correspond to each other.  You should not need to adjust the air speed to this unit. 

Содержание SG1300

Страница 1: ...1 Synergy Grill 900 User Engineer Installation Conversion Guide...

Страница 2: ...ation Section 1 5 Gas Supply Section 1 6 Electrical Supply Section 1 7 Water Supply Section 1 8 Starting up and Shutting Down Section 2 1 Testing and Purging Section 2 2 Checking Pressures Section 2 3...

Страница 3: ...3 Section 3 3 1 Changing Injectors for Natural Gas Section 3 3 2 Reinstating the Internal Gas Valve Regulator for Natural Gas Section 3 3 3 Nat Gas Data Plate...

Страница 4: ...gas valves This appliance is CE marked declaring the compliance with EC directives The Gas Types and Pressures for the destined country are stated on the appliance Data Plate The instructions through...

Страница 5: ...ht oil such as vegetable oil can smooth out the pitting and stop any food from sticking Fresh unoiled cast iron cooking bars are also prone to rust if you do not season them from the start First week...

Страница 6: ...our warranty registration and return to Active Food Systems to start your warranty This unit is heavy do not attempt to lift with less than four people 1 2 Technical Information Gas Type Width Depth N...

Страница 7: ...nput kW 11 4 11 0 11 0 12 6 Total nominal rate m3 h 1 206 1 32 1 28 0 994 kg h Nominal NET heat Input kW burner 5 7 5 7 5 7 6 3 Nominal Rate burner m3 h 0 603 0 69 0 65 0 497 kg h Burner pressure mbar...

Страница 8: ...access to the Synergy Grill This can be blocked by tea towels trays or anything thin enough to store under the unit 1 4 Ventilation The unit must be installed in a draught free position Adequate vent...

Страница 9: ...to the appliance to allow a fast shut off during an emergency or routine servicing 1 6 Electrical Supply This unit is supplied via a 5A 3 pin plug at 240v This unit must be earthed or the appliance w...

Страница 10: ...mated ignition system via the Front Switches Each Front Green Rocker Switch is assigned in order of each burner Left Switch controls the Left Burner and so forth Pressing this switch will cause the ap...

Страница 11: ...wing so when the gas valve opens the manometer will increase again SO if you have 1 0mbar of fan pressure already showing and the Gas Valve opens and you then increase the final pressure to 15 0 mbar...

Страница 12: ...tural Gas 2 2mm jet using a 9mm socket and keep in a safe place in case you need to convert back to Natural Gas and replace with 1 5mm Jet Screw down the burner again A new Gasket may be required 3 1...

Страница 13: ...re as possible If the outlet pressure point has a significant drop in pressure from the inlet please go through step 3 1 2 again 3 3 Converting to Natural Gas Natural Gas Jets 2 2mm should have been k...

Страница 14: ...Screw and keep safe for when you need to convert back C Connect your manometer to the Outlet Pressure Post Follow steps 2 2 C D and set burner to 15mbar D Replace the Brass Regulator Cover Screw Nat...

Страница 15: ...15 Synergy Grill 900 User Engineer Servicing Cleaning Guide...

Страница 16: ...ing 22 Spares List 23 24 Section 7 Installation Tips and Advice for Gas Installation Engineer 25 Section 4 1 Flame Dropping Out Through Service Section 4 2 Changing an Ignitor Section 4 3 Changing a V...

Страница 17: ...se book your engineer in for an AM service before the unit is switched on for greater ease of work If the appliance must be worked on whilst it is still hot always use heat protective gloves when hand...

Страница 18: ...off causing the system to lock out The detection system will send a False Signal back to the Microgas Controller if the electrode is contaminated with salts fats and oils To stop this simple problem w...

Страница 19: ...he unit has attempted this three times you must check the gas supply has not dropped coming from the Outlet Port on the internal Gas Valve 2 2 C D nothing is blocking the Burner or the Gas is connecte...

Страница 20: ...at the time please wait up to 20 seconds before you can hear the fan noise Remove the grill top panel to access the screws holding the panel in place Figure 1 Remove the MicroGas controller by disconn...

Страница 21: ...d screw into the metal fan tray 4 6 Burner Injector Cleaning Burners and Jets require periodic cleaning to ensure all ports and apertures are free from debris and blockages Failure to periodically cle...

Страница 22: ...ront Red Fault Light on Yes No Check the Air Pressure Switch Is it blocked with grease Remove the air hose from the brass air nipple and blow with your mouth it should click with pressure Internal gas...

Страница 23: ...23 6 Wiring Diagram...

Страница 24: ...from around the burner and the flame sensor igniter 3 Use a piece of abrasive strip to remove the salts and oils from the white ceramic of the flame sensor and metal electrode as per the picture 4 Wi...

Страница 25: ...l Replacement Ceramic Kit SG630 CERAMIC900 Synergy Grill Replacement Ceramic Kit SG900 CERAMIC1300 Synergy Grill Replacement Ceramic Kit SG1300 C4065 C6065 Synergy Grill Honeywell Air Pressure Switch...

Страница 26: ...l Ceramic Cap SG90 CF Synergy Grill Ceramic Ring TRANSFORMER Synergy Grill Transformer 36J41K 200 Synergy Grill Gas valve 630CONVERSIONKIT Synergy Grill Conversion Natural LPG Kit SG630 900CONVERSIONK...

Страница 27: ...y ceramic block is open and you can see the smaller hole in the metalwork behind the ceramic Ensure the Ceramic Ring is orientated correctly the three nodules should be at the bottom of the ring and t...

Страница 28: ...28...

Отзывы: