PRX-40B
16
normal mode.
Delete cards:
After entering set-up mode key-in code 25 (delete card by index) and key-in a 4 digit index. 2 short beeps
will indicate that the index was deleted successfully. After swiping all cards press 7&8 simultaneously
(mandatory) (press
Enter
in terminals that consist of an
Enter
key) in order to revert to normal mode.
Terminology
Card Only - Control is performed by Card only.
Global Code only - common global code (4 digit code – used by all card-holders).
Card or code - Control is performed by Card or keying-in number of card (the length of the keyed-in num-
ber must be identical to the defined card length).
Card and Global Code - Control is performed by Card and a common global code (four digit code – used
by all card-holders).
Card and PIN Code – Control is performed by Card and a personal four digit code. This mode is the most
secure.(4 digit code – used by each card-holder).
6.1.1
General definitions
Open Door
Access can be given by using a Master Code. After entering “Programming Mode,” enter “0”.
Open Door Time
It is possible to adjust the “window” of accessibility during which a door opens when accessed. To change
the accessibility time, after entering the “Programming Mode,” enter “10” and then four digits. For exam-
ple if you enter 0015, the accessibility time is 1.5 seconds.
Set Global Code
You can change a Global Code by way of “Instruction Code” – 15. After entering “Programming Mode”
enter “15” and afterward a four digit number that will be the new Global Code.
Set New Master Code
The Master Code can be change by way of “Instruction Code” – 13. After entering “Programming Mode”
enter “13” followed by a eight digit number that will serve as a new master Code.
Note:
It is recommended to change master code when setting up.
Erase All
Warning:
!
Cards can not be restored after erased!
After entering the “Programming Mode,” enter “6” and then eight digits Master code.
6.1.2
Indicators definitions
After entering setup mode:
Input Operation Mode
Code 30 -->
0 = Door open request button
As a result the door will open and the output = bypass
1 = Door sensor
As a result the output = alarm will be activated (led/buzzer)
Sensor type
Code 31-->
0 = The sensor will function as Normally Open.