PRX-40B
12
5.
Operation
5.1
Set-up mode
PRX-40/A programming can be divided to three categories:
1.
Access Cards configuration (authorized personnel)
2.
General definitions
3.
Indicator definitions
All definitions of Management modes are listed in the table below.
The codes in the table below can be used only after completing set-up mode as follows:
Step 1:
Press 3 times simultaneously on function keys 1 & 2 (each time will be followed by a short beep
and an orange led will be lit).
Step 2:
Enter the 8 digit master code (the default number is 12345678). Then insert the relevant set-up
code (see next page).
5.2
Access cards configuration (Set-up codes)
Input
Indicator signalling
1st 1&2
Short beep+2nd red led ON
2nd 1&2
Long beep+2nd red led ON
3rd 1&2
2 long beeps+2nd green led flashes
Name
Code
Parameter
Comments
Default
Work mode
8
0 -
1 -
Stand alone
Online
From version 3.04
Until now this was done in
jumper JP20.
Control Door
0
Enter Master code and
press 0.
Reset alarm
4
When the alarm is in latch (turned ON)
Check ID Address
7
Long buzzer - tens
Short buzzer - unique
Door opening time
10
000-255
In 1/10 seconds step (0 to 25.5
sec.)
3 sec.
Card reading/check
parameters
11
1,2- Start position (01-37)
3,4- Length (01-06)
5,6- Total Characters
01
16
00