PRX-40B

10 

Wire connection diagram

4.4

Connecting to a Master controller

Содержание PRX-40 B

Страница 1: ...PRX 40 B Product Manual ...

Страница 2: ... use of the information contained herein While every precaution has been taken in the preparation of this manual Synel Industries Ltd assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained herein DCM and SY are trademarks of Synel Industries Ltd All trade names referenced herein are either trademarks or reg...

Страница 3: ...tallation 7 4 1General 7 4 2Finding the best location for the unit 7 4 3Mounting the unit 8 4 4Connecting to a Master controller 10 4 5Jumpers 11 4 6Dismounting the terminal 11 5 Operation 12 5 1Set up mode 12 5 2Access cards configuration Set up codes 12 6 Access cards configuration 15 6 1Management of Access Cards authorized personnel 15 6 2Communication 17 ...

Страница 4: ...ashes and makes the PRX 40 B ideal for exposed environments that can easily damage standard unprotected terminals Setting the PRX 40 B for maximum security is simple and is enabled by use of an eight digit code chosen by the customer Additional access controls have been incorporated to greatly improve security When working in online mode as with a Master unit PRX 40 B uploads data from the from th...

Страница 5: ...otection Reverse voltage protection On board RS 232 programming of 64 kB flash memory 2 2 Physical specifications Dimensions 15 5 x 7 x 6 1 cm Weight 350g Operating temperature 22 to 50_C Relative humidity 95 2 3 General characteristics Output relay rating 24 Vdc 3A Alarm sensor output TTL level max 16 mA Alarm set at High Sensor Input 9 18V 10mA in Non dry contact mode Power supply 12 to 15 Vdc D...

Страница 6: ...tor both connected to a loop antenna In addition to operating as an access terminal PRX 40 B includes additional circuitry for storing card holder data Operating power for the unit comes from a wall adapter which is be factory connected to either the back or bottom of the unit Power LED Red Status LED Green OK Red Wait Keyboard Bell button ...

Страница 7: ... adaptor dedicated to the proximity unit Make sure the adapter carries a safety recognition marking such as UL CSA or CE If you are installing more than one Synel proximity reader make sure the readers are installed at a distance of at least 50 cm from one another 5 times the unit reading limit Use a linear power supplier and not a switching power supplier which generates an electro magnetic field...

Страница 8: ...crete as needed 5 Thread the cable through the wall and connect to external components as needed See the Connect wires section below for cable connection according wire color coding 6 Mount the panel to the wall and adjust it so that it is straight and the cable is in place 7 Slide the unit downward onto to the mounting panel The hinges at the side of the panel 1 should slide into the track of the...

Страница 9: ...sent Color Code 1 Vin Power VCC Red 2 Gnd Black 3 TxRx RS 485 Grey 4 TxRx RS 485 Purple 5 TxD RS 232 White 6 RxD RS 232 Green 7 Tamper Control Brown 8 Normal Neutral C Blue 9 Normally Closed N C Yellow 10 Normally Open N O Orange 11 Bell 1 Pink 12 Bell 2 Light green 13 optional as needed Light blue 14 optional as needed Brown White or Brown Black ...

Страница 10: ...PRX 40B 10 Wire connection diagram 4 4 Connecting to a Master controller ...

Страница 11: ...ng of the master CPU 2 3 Closed 1 2 closed JP11 TH PSEN Programming must be closed when programming the master CPU Open JP12 SMD Tamper switch enabled 1 2 closed Tamper switch disabled 2 3 closed 2 3 closed JP20 T H Closed Stand alone Open Online with Master Closed up to version 3 04 later set via Setup JP21 T H Contacts switching protection in DC closed Contacts switching protection in AC open Cl...

Страница 12: ... default number is 12345678 Then insert the relevant set up code see next page 5 2 Access cards configuration Set up codes Input Indicator signalling 1st 1 2 Short beep 2nd red led ON 2nd 1 2 Long beep 2nd red led ON 3rd 1 2 2 long beeps 2nd green led flashes Name Code Parameter Comments Default Work mode 8 0 1 Stand alone Online From version 3 04 Until now this was done in jumper JP20 Control Doo...

Страница 13: ...sly Mode 5 only with PRintX Delete card from list using card 21 Card Insert card using keyboard 22 In Operation mode 12 press key no 4 to enter mode 4 1 Key in card number 2 Enter pin code Terminal reverts to 1 Fingerprint In Operation Mode 12 press key no 6 to enter Mode 6 1 Key in code depends on card length 2 Place finger Terminal reverts to 1 To revert to normal mode press 7 8 simultaneously o...

Страница 14: ...oor monitor button 38 0 1 no buzzer buzzer If door is open too long sound buzzer Version 3 04 Duress code enable dis able 50 0 1 Disable Enable Activating alarm and relay out put Alarm mode 51 0 1 Latch LED is on Pulse LED is off 1 LED is off depending on pulse time code 52 Alarm pulse activating time 52 0000 9999 Key in time in a four digit for mat 10 sec 0010 0 sec Define duress code 53 0000 999...

Страница 15: ...eted successfully After key ing in all card numbers press 7 8 simultaneously mandatory press Enter in terminals that consist of an Enter key in order to revert to normal mode Using Card Build list After entering set up mode key in code 20 Insert card to list by card and swipe all relevant cards After each swiped card 2 short beeps will indicate that the number was registered successfully After swi...

Страница 16: ...ing Programming Mode enter 0 Open Door Time It is possible to adjust the window of accessibility during which a door opens when accessed To change the accessibility time after entering the Programming Mode enter 10 and then four digits For exam ple if you enter 0015 the accessibility time is 1 5 seconds Set Global Code You can change a Global Code by way of Instruction Code 15 After entering Progr...

Страница 17: ...d parameters Refer to how the proximity track will be read Reset alarm In set up mode after keying in code 51 key in 4 to shut off the alarm 6 2 Communication Interfacing the host is performed via the Master unit Communication between the master unit and the ter minals is performed at 19200 bps Downloading card numbers from Master to terminals As of Master version 3 20 there is an additional optio...

Страница 18: ...ines of less than 5 KVA Cables should not be within 60 cm 2 feet of power lines in the 5 10 KVA range Cables should not be within 1 5 meters 5 feet of power lines of more than 10 KVA The cables should not run parallel to power lines for more than 15 meters 49 feet It is best to use a single cable for the communication line If it is not possible to use a continues cable only one indoors connection ...