Procedure G. RS-422–to–RS-232 TOD Converter Installation
Step
Procedure
1
Secure the provided mounting plate to the RS-422–to–RS-232 TOD converter,
using the two provided screws. The plate may be attached to the top or front of
the converter, depending on the desired surface (for example, a rack or cabinet)
to which the converter will be mounted (see Figure 32).
Notes:
1. Due to distance constraints, the converter must be placed no more than
1000 ft from the TimeSource 3500 Shelf, and no more than 50 ft from the
device receiving the time code.
2. The converter dimensions are 3 in. by 2.5 in by 1 in.
3. The mounting plate dimensions are 3 in by 2 in.
2
Secure the converter to the desired surface, using the slots in the plate and user-
supplied bolts.
3
Install a user-supplied Category 5 four-pair RS-422 cable, with RJ-45 connectors
on each end, between the TimeSource 3500 Shelf and the converter (see
Figure 33).
4
Install a user-supplied RS-232 cable, with DB-25 connectors on each end,
between the converter and the device receiving the time code (see Figure 33).
See Table D for the DB-25 connector pinouts.
End of Procedure
Содержание TimeSource 500
Страница 1: ...TimeSource 3500 GPS Primary Reference Source 097 72050 01 Issue 7 August 2003 ...
Страница 6: ...6 TimeSource 3500 Contents 097 72050 01 Issue 7 August 2003 ...
Страница 85: ...3 Chapter Installation This chapter is the sequential order of procedures for installation and power up ...
Страница 161: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Страница 271: ...6 Chapter Specifications This chapter provides equipment specifications ...
Страница 297: ...Index ...