RJ-422–to–RS-232 TOD Converter
If using time-of-day (TOD), and the device receiving the time code
accepts an RS-232 signal instead of an RS-422 signal (for
example, a Cisco router), an RJ-422–to–RJ-232 TOD Converter Kit
is required (ordered separately, part number 093-72000-98).
The RJ-422–to–RJ-232 TOD Converter Kit consists of a mounting
plate with a female RJ-45 connector, a female DB-25 connector, a
TOD converter, and two screws.
Install the converter anywhere (for example, on unused space on a
rack) within 1,000 cable feet of the TimeSource 3500 shelf, and
within 50 cable feet of the device receiving the time code.
The user must supply two cables. One cable is a Category 5 four-
pair RS-422 cable, 1,000 feet maximum, with RJ-45 connectors on
each end. Route this cable between the TimeSource 3500 Shelf
and the converter.
The other cable is an RS-232 data communications cable, 50 feet
maximum, with a 25-pin male D-type connector and another
connector determined by the device receiving the time code. Route
this cable between the converter and the device receiving the time
code.
Содержание TimeSource 500
Страница 1: ...TimeSource 3500 GPS Primary Reference Source 097 72050 01 Issue 7 August 2003 ...
Страница 6: ...6 TimeSource 3500 Contents 097 72050 01 Issue 7 August 2003 ...
Страница 85: ...3 Chapter Installation This chapter is the sequential order of procedures for installation and power up ...
Страница 161: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Страница 271: ...6 Chapter Specifications This chapter provides equipment specifications ...
Страница 297: ...Index ...