ND-CLK User Manual- Rev 1.0.1 - Sep-08
a
Symmetricom
®
, Inc
APPENDIX C - MOUNTING
The ND-CLK is designed for surface mounting on a wall.
[Note: Power and/or low voltage signal wiring should be provided and installed
according to local electrical codes to access the clock from the rear.]
Mount the bracket on the wall/conduit box and attach the power & signal cables, secure
the clock to the bracket using the retaining screw.
Caution : Do not route power or signal cables between the case and the wall (along
the exterior of the wall), which may pinch the power or signal cable and create a
hazardous condition.
A dimensioned drawing has been provided to show a keep out zone for the rear of the
clock. In order to allow the clock to be mounted flush against the surface of the wall, do
not route wires or connectors in the keep out zone
.
In addition, a template of the mounting bracket has been provided with the clock to locate
the center of the wiring box/compartment relative to the center of clock.
A mounting bracket is supplied which
has been designed to fit on either a
standard 2”x 4” or 4” x 4” conduit
box or wiring compartment.