3. Windows SDK
bcReqManufData
Description: Returns manufacture data from the board.
Note: See the header file for ManufData structure to understand values being returned.
bcSetGain
Prototype
int bcSetGain (INT gain);
Packet
0x25
Input Parameter
int gain = oscillator control filter gain value.
Returns
RC_OK On Success
RC_ERROR On Failure
Description: Modifies the internal oscillator frequency control algorithm.
Note: This command is not required for standard operation of the device. Be sure to understand the
effects of this operation before utilizing this command.
bcSetGenOff
Prototype
int bcSetGenOff (INT Offset, UCHAR half)
Packet
0x1C
Input Parameter
INT offset = hours from input time source. (-16 - +16). UCHAR half = half
hour increment
0: No Half Hour increment
1: Add Half Hour increment
Returns
RC_OK On Success
RC_ERROR On Failure
Description: Programs the board time code generator to operate at an offset from UTC.
bcSetJam
Prototype
int bcSetJam (INT jam_ctl);
Packet
0x21
Input Parameter
INT jam_ctl = 0 or 1
0 = Jam-Synchs Disabled
1 = Jam-Synchs Enabled
Returns
RC_OK On Success
RC_ERROR On Failure
Description: Modifies the internal oscillator frequency control algorithm.
Note: This command is not required for standard operation of the device. Be sure to understand the
effects of this operation before utilizing this command.
- 120 -