Symeo LPR
®
-System
LPR
®
-2DB
Product Documentation
Commissioning
Copyright © Symeo 2012
Page 69 of 132
7.4.2
field.ini
This file contains the transponder coordinates (coordinates of mounted integral stations), if
using operation mode 1, 2a or 3a. If using operation mode 2b or 3b the transponder
coordinates are saved in the master transponder.
Figure 51
– field.ini (example)
The transponder coordinates is only be done in mode 1 (Basic Cell),
mode 2a (Managed Cell) and mode 3a (TDOA). In mode 2b (Managed
Cell) and 3b (TDOA) the coordinates are entered directly in the file for
the DSP of the master transponder (compare chapter 7.2.2 - file
„stationXXM_config.txt“).
{cell_1}
Every LPR-2DB cell is identified with
{cell_#}
, where
#
is the number of the cell.
[Coordinates]
The coordinates (x, y, z) of every transponder of this cell.
The columns have the following meaning:
ID
x
y
z
Station-ID
(0..5 for transponder,
30 for master)
x-coordinate of
transponder
y-coordinate of
transponder
height of transponder
All positions must be entered in m and with a decimal point.