Symeo LPR
®
-System
LPR
®
-2DB
Product Documentation
Commissioning
Copyright © Symeo 2012
Page 66 of 132
Establish a connection between your PC and the mobile station (7.3.1 or 7.3.2)
Keep ready the following data of the master transponder: group-ID, station-ID, fsk-
channel. These data can be read out from the short ID labeled on the master
transponder. Example short-ID 101: The first 2 digits for the cell-ID are consistent with
the group-ID. The third digit is the station-ID. The FSK-channel is consistent with the cell-
ID/ group-ID for the first 40 cells.
Open a FSK-connection with the master transponder:
Figure 47
Enter in the terminal window
key “5” for “fsk serial
terminal”.
Enter “t” for transponder
Enter the group-ID of the
transponder
Enter the station-ID of the
transponder (0…5)
Enter the FSK channel
Enter “1” for the antenna
port of this station
Figure 48
Press “Enter”
After a moment the mobile unit
is connected via radio channel
with the transponder. This is
indicated with 2 hash keys at
the beginning of the row.
Now, you can upload the configuration file of the DSP of the transponder. Do the following: