2
The room where the fireplace is operated should not be
smaller than 44 cubic meters (1550 cubic feet). The area
of the room needs to be at least 20 square meters (215
square feet) with a ceiling height of 2.3 meter (8 feet).
it is not recommended to use more than one fireplace at a
time in one room.
Never leave a fire unattended at any time.
The fireplace is not suitable for heating purposes.
The burner and fuel must not be exposed to direct heat
such as direct sunlight and other heating sources.
do not place any flammable material / flammable liquid
within 1 meter (40 inches) around the fireplace. A safety
distance of at least 2 meters (80 inches) should be kept
from any window and curtain.
Avoid drafts in the room where the fireplace is located.
pARTS LIST:
Ethanol Insert .......................................................................................... 1
1) Burner holder..................................................................................... 1
2) Burner (max capacity 800 mL) ........................................................ 1
3) Funnel ................................................................................................. 1
A) Top panel ............................................................................................ 1
B) Base panel .......................................................................................... 1
C) Front Panel ......................................................................................... 1
D) Left front panel .................................................................................. 1
E) Right front panel ................................................................................ 1
F) Left side panel .................................................................................... 1
G) Right side panel ................................................................................. 1
H) Corner panel ...................................................................................... 1
J) Left corner support ........................................................................... 1
K) Right corner support ......................................................................... 1
R) Wood connectors .............................................................................. 2
S) Mounting brackets ............................................................................ 4
T) Mounting screws ............................................................................... 8
W) KD screws .........................................................................................49
X) Plastic connectors ............................................................................ 13
Y) SELF REPAIR SET
Touch-up repair paint (bottle) .............................................................. 1
L shape bracket ....................................................................................... 2
Screws for L shape ................................................................................. 8
Plastic connector ..................................................................................... 1
KD screws ................................................................................................ 3
KD nuts ..................................................................................................... 3
Z) WALL ANCHOR SAFETY CABLE
Wall anchor ............................................................................................. 1
Screw for wall anchor ............................................................................ 1
Screw for mantel ..................................................................................... 1
Safety cable ............................................................................................. 1
TOOL REQUIRED: PHILLIPS HEAD SCREWDRIVER