![background image](http://html.mh-extra.com/html/sygonix/touch-tx5/touch-tx5_operating-instructions-manual_1416953052.webp)
52
The home technology brand for the entire house. More information at
www.sygonix.com
Connection chart:
COM1
NO1
NC1
COM2
NO2
NC2
N, L
Terminal clamps for mains voltage
COM1, NC1, NO1
Terminal clamps for heater
COM2, NC2, NO2
Terminal clamps for cooling device
RT1, RT2
Terminal clamp for external temperature sen-
sor
The room thermostat offers the option of connecting
both a heater (electrical heater) and a cooler (fan, air
conditioner). For this, it is mandatory that the correct
terminal clamps are selected; see above.
For the respective device to be correctly activated/deac-
tivated depending on the temperature, the setting menu
“INSTALL SETTINGS” can be selected in the function H1
“HEAT OR COOL” (“HEAT” = heating mode, “COOL” = cool-
ing mode).