28
2) Reset of the access system without teaching in a master transponder
If a master fingerprint is stored, it is retained and is not deleted.
•
De-energise the access system and wait for the LED to go out.
•
Press the door opener button and hold it down.
•
Reconnect the access system to the voltage/power supply. The access system emits two beeps.
•
Wait for around 5 seconds, keep the door opener button pressed and do not release it.
•
The access system emits a beep and the LED lights up red.
•
Now release the door opener button; the access system is now in standby mode again. All settings have been reset
to the default settings; however, there is no master transponder for teach-in/deletion of user transponders.
Table for default settings:
Function
See chapter
Default setting
Master code
8. b)
123456
Access mode
8. i)
Transponder or fingerprint
Changeover contact activation time
8. j)
5 seconds
Protection against incorrect entries
8. k)
switched off
Alarm duration for protection function
8. l)
1 minute