15. Technical data
a)
Access system
Power supply ........................................12 - 18 V/DC
Current consumption ............................standby < 30 mA
Frequency range ..................................124.6 - 125.4 kHz
Transmission power..............................11.62 dBm
Max. reading distance ..........................approx. 3 cm
Data retention in case of a power cut ...yes
Suitable transponders ...........................Commercially available EM transponders for frequency 125 kHz
Output ...................................................Potential-free single-pole changeover contact (relay)
Max. contact rating 24 V/DC, 2 A
Adjustable switching time (1 - 99 seconds or toggle mode; default setting: 5
seconds)
Wiegand connection .............................Yes (output = 26-bit protocol, input = 26/34-bit protocol with automatic
detection)
Memory for transponders .....................900 (of which 890 user transponders and 10 visitor transponders)
Memory for fingerprints
.........................
100 (of which 99 user fingerprints and 1 master fingerprint)
Mounting location .................................indoors/outdoors
Protection class ....................................IP66
Ambient conditions ...............................
temperature -25 °C to +60 °C
Cable length .........................................approx. 25 cm
Dimensions ...........................................115 x 70 x 25 mm (H x W x D)
Weight ..................................................approx. 190 g
b)
IR remote control
Operating voltage .................................3 V/DC via 1x battery of type CR2025 (lithium button cell)
IR range ................................................max. approx. 1 m