m) Teaching in visitor transponders
The access system can store up to 10 different visitor transponders. Memory numbers 990 - 999 are provided for
these transponders.
For each of the visitor transponders, you can program the number of access attempts (1 - 10 attempts can be set) after
which the transponder will become invalid. For example, you can program a visitor transponder in such a way that it
only allows access once. The visitor transponder then becomes invalid.
Once the number of access attempts programmed for the visitor transponder has been used, the access
system automatically deletes the transponder from the memory. The memory number is then free for pro-
gramming another visitor transponder.
For information on deleting the visitor transponder prematurely (for example, if the complete number of
access attempts was not used), see 8. e).
We recommend that you create a table and fill in all access data, including visitor name, number of access
attempts, memory number, transponder number. For visitor transponders, you should also use transpond-
ers with a different colour or shape.
Proceed as follows:
• Start programming mode as outlined in 8. a) so that the LED flashes red.
•
Enter the programming code to teach in visitor transponders. The LED lights up yellow.
•
Enter the number of times the visitor transponder may be used ( ..... , where ‘0’ stands for 10x use).
Example 1: = the visitor can use the transponder 2x, it then becomes invalid
Example 2: = the visitor can use the transponder 10x, it then becomes invalid
• Confirm the number with the
button.
•
Enter the memory number (990 ..... 999) to which the visitor transponder is to be stored.
Example: = Store the transponder to memory 995
• Confirm the memory number with the
button.
If the memory number has already been assigned, the access system emits 3 quick beeps and the LED
flashes red. It is, therefore, not possible to overwrite a memory. Start by deleting the respective memory
(see 8. e) before another visitor transponder can be stored there.
•
Hold a transponder in front of the RFID sensor. Once a new transponder is recognised, the access system emits a
short beep and the transponder is stored.
If the transponder has already been taught in, the access system emits 3 quick beeps and the LED flashes
red. The same transponder cannot be taught in more than once.
•
If you wish to teach in another visitor transponder, start by entering the number of access attempts.
•
Exit teach-in mode with the
button. The LED flashes red again. You can now carry out further programming or
exit programming mode with the button.