Fitted equipment
63
The quantity of air can be individually adjusted
at the air flap (f), for warm air distribution.
In centre position 50% of the warm air is
distributed to each outlet.
Use the fan duct with 72 mm and if the fan
ducts are of different lengths or on sides with a
greater heat requirement. This means that the
air output can be used to the full on this side.
By adjusting the air flap (f) the quantity of air
can be increased individually. This means that
the air out-put on the other side is reduced.
If the air output drops or the operating noise
increases, the fan impeller wheel may be
severely soiled.
cleaning
(with switched off appliance!) We recommend
removing dust which has collected on the heat
exchanger and base plate of the heater and on
the impeller wheel of the Trumavent fan, once
a year before the heating season starts. Clean
the impeller wheel carefully using a brush or
tooth brush.
truMa ultraHeat addItIonal
electrIc HeatInG
For trumatic s 3002 heaters
Function description
Truma-Ultraheat is an additional 230V electric
heater for the LPG heater models Trumatic S
3002/S 5002.
Heater operation is basically possible with gas
only, electricity only or simultaneously with
electricity and gas.
When using simultaneously the electrical unit
will switch itself off before overheating occurs
as a result of the stronger gas burner.
When using electrical only we recommend to
set the fan control on position 3 (manual or
auto), remembering to set the output level to
2000W (ensure that the fuse protection for the
power supply of the camp site is sufficient).
If more than 2kw are required (heating up/cold
temperatures) you must refer back using gas
operations as the 230V electrical operation is a
secondary heater only.
The electric heater can also be operated
without the Trumavent fans.
WarnInG: surfaces become hot in use,
guards provided do not give full protection
to the young or elderly
operating instructions
before operating the heater for the first
time it is essential to observe the operating
instructions, enclosed with the heater .
control panel with thermostat
a = Rotary switch “Off”
b = Rotary switch “On”
power settings:
500 - 1000 - 2000 W
c = Rotary control knob for room
temperature (illuminated by green
indicator lamp “operation”)
Содержание 2009 Charisma
Страница 18: ...Towing code 21 ...
Страница 25: ...Safety security Fire 28 Escape paths 29 Children 29 Ventilation 29 Security 30 ...
Страница 34: ...Services 36 Typical gas schematic drawing ...
Страница 44: ...Electrics 47 ...
Страница 116: ...Maintenance 120 Spare Wheel Carriers The telescopic frame tubes should be lubricated periodically ...
Страница 117: ...Fault finding Water 122 Gas 124 Cassette Toilet 125 ...