Fault finding
123
Fault
cause
remedy
Water flows from hot tap
but has reduced flow
from cold
Cold water pipe kinked preventing flow
Blockage in cold pipe line
Cold tap not connected
Cold tap failed or blocked
If a water filter is fitted, the cartridge is
exhausted
Check and re-route if necessary
Disconnect pipes after 1st Y connector and check up to tap
Refer to installation instructions
Disconnect and inspect
Replace cartridge
Reduced flow from both
hot and cold taps
Battery condition low causing pump to
run slowly
If new taps have been fitted they may be
restricting flow
Pump needs servicing
Partially blocked pump filter or in-line filter,
if fitted
Pump outlet pipe kinked restricting flow
Water leak
Check battery state of charge, refer to electrical supply note
Disconnect and check that they have at least 1/4” (6.3mm) bore
Refer to pump servicing instructions
Dismantle and clean if necessary
Check and re-route if necessary
Check all water connections
Reduced flow from
either tap
Y’ connector(s) fitted incorrectly
Pipe kinking restricting flow
Bore size difference in taps
Refer to installation instructions
Check and re-route if necessary
Use taps of equal bore size
Warm water flows out of
cold tap
Hot water back-feeding into cold line, usually
if mixer tap or single outlet hot and cold taps
being used
Fit non-return valve in cold supply, near tap
If pump motor runs
steadily and will not stop
Battery voltage may be too low
(below 10.5 volts)
Check that there is water in the container
Adjust switch and/or re-charge battery
Check all connections in pipework
Содержание 2009 Charisma
Страница 18: ...Towing code 21 ...
Страница 25: ...Safety security Fire 28 Escape paths 29 Children 29 Ventilation 29 Security 30 ...
Страница 34: ...Services 36 Typical gas schematic drawing ...
Страница 44: ...Electrics 47 ...
Страница 116: ...Maintenance 120 Spare Wheel Carriers The telescopic frame tubes should be lubricated periodically ...
Страница 117: ...Fault finding Water 122 Gas 124 Cassette Toilet 125 ...