Fitted equipment
58
1. Check that the safety/drain valve in the
cold-water intake is closed. Lever should
be in the horizontal position, position (e).
2. Open the hot tap in the bathroom or kitchen
with pre-selecting mixing taps or single
lever fittings set to hot.
3. Switch on power for water pump (main
switch or pump switch). Leave the tap open
to let air escape while the water heater is
filling. The heater is filled when water flows
out of the tap.
Residues of frozen water can prevent filling
if there is a frost. The water heater can be
defrosted by switching on the heater for a
short period (max 2 mins). Frozen pipes can
be defrosted by heating the room.
Note: If just the cold water system is being
used, without water heater, the heater tank
is also filled up with water. In order to avoid
damage through frost, the water contents must
be drained by activating the safety/drain valve,
also when the heater has not been used. As an
alternative, two shut-off valves, resistant to hot
water, can be fitted in front of the cold and hot
water connection.
draining the water heater
1. Disconnect power for water pump (main
switch or pump switch).
2. Open hot water taps in bathroom
and kitchen.
3. Open safety/drain valve: Lever in vertical
position, (Fig. 1) position (f).
4. The water heater is now drained directly
to the outside via the safety/drain valve.
Check that the water contents have been
completely drained (10 litres).
Gas operating instructions
attention: never operate the water heater
without water in it!
If the wall cowl is positioned close to an
opening window (or hatch) - in particular
directly under it - it must remain closed
when the water heater is in use (see
warning plate) .
1. Remove cowl cover.
Fig . 2
Fig . 3
2. Open gas cylinder and open quick-acting
valve in the gas supply line.
3. Select required water temperature at rotary
knob (c) infinitely variable from approx. 30°
to 70°C.
4. Switch on water heater at the rotary switch
(a) on the control panel, green indicator
lamp “Operation” lights up.
5. If there is air in the gas supply line, it may
take up to a minute before the gas is
available for combustion. If the appliance
switches to “Failure” during this period,
switch off the appliance - wait 5 minutes -
and switch on again!
switching off (gas operation)
Switch off the water heater at the rotary switch (b).
drain the water heater if there is a risk
of frost!
If the water heater is not to be used for a longer
period, mount cowl cover (non-observance
Содержание 2009 Charisma
Страница 18: ...Towing code 21 ...
Страница 25: ...Safety security Fire 28 Escape paths 29 Children 29 Ventilation 29 Security 30 ...
Страница 34: ...Services 36 Typical gas schematic drawing ...
Страница 44: ...Electrics 47 ...
Страница 116: ...Maintenance 120 Spare Wheel Carriers The telescopic frame tubes should be lubricated periodically ...
Страница 117: ...Fault finding Water 122 Gas 124 Cassette Toilet 125 ...