Fitted equipment
61
cassette (see changing batteries, page 62).
thermostat
Set the required room temperature at the
control knob (numbers 1-10). For an average
room temperature of approx. 22°C we
recommend setting:
3-5 Without the Trumavent Fan (switched on)
4-8 With the Trumavent Fan
switching off
Set control knob to “0”. If turning off for a long
period of time, close the quick-acting valve in
the gas supply line. Close valve of gas cylinder.
Important Operating Notes
1. If the gas supply line is filled with air, it
may take up to a minute before the gas
becomes available for combustion. During
this time depress the control knob and
continuously operate the Piezo ignitor until
the flame ignites.
2. You will have to find out the exact
thermostat setting yourself, depending on
how much heat you need.
3. Repairs are only to be carried out by a
competent service engineer.
attention: a new o-ring must always be
installed after dismantling the exhaust duct .
a = control knob
b = Integrated control panel for
trumavent fan teb
c = piezo ignitor or automatic ignitor
d = Flame observation window
e = name plate (remove casing)
f = thermostat probe
In the case of left-handed installation, the
parts are arranged on the other side .
4. Any alteration to the appliance (including
exhaust duct and cowl) or the use of spare
parts and accessories, which are important
to the function of the heater and which are
not original Truma parts, as well as the non-
observance of the installation and operating
instructions, will lead to the cancelling of the
guarantee and exclusion of liability claim.
5. During the initial operation of a brand new
appliance, a certain amount of fumes and
a slight smell may be noticed for a short
while. Remedial action is to immediately
run the heater at maximum output and to
ensure adequate room ventilation.
6. In winter, before switching on the heater,
remove all snow from the cowl.
7. Inspect the exhaust duct and all
connections at regular intervals and always
whenever there is a blowback (misfire). It is
essential that the exhaust duct is installed
so that it slopes upwards over its whole
length and is securely fixed with several
clamps. Never place any object on the
exhaust duct, since this could result in
damage. The exhaust duct connection to
both the heater and the cowl must be firm
and well sealed.
Do not operate heaters with incorrectly
fitted or damaged exhaust ducts.
8. Never allow the warm air outlet on the
heater to be obstructed in any way. For
Содержание 2009 Charisma
Страница 18: ...Towing code 21 ...
Страница 25: ...Safety security Fire 28 Escape paths 29 Children 29 Ventilation 29 Security 30 ...
Страница 34: ...Services 36 Typical gas schematic drawing ...
Страница 44: ...Electrics 47 ...
Страница 116: ...Maintenance 120 Spare Wheel Carriers The telescopic frame tubes should be lubricated periodically ...
Страница 117: ...Fault finding Water 122 Gas 124 Cassette Toilet 125 ...