ELECTRICAL SYSTEM 10-7
• Faulty generator coil or
disconnected lead wires
• Faulty generator
• Faulty regulator/rectifier
Measure the continuity of the generator coil.
(
:
10-9)
Measure the generator no-load voltage.
(
:
10-10)
Continuity
Correct
Inspect the regulator/rectifier.
(
:
10-10)
Correct
Inspect the wires.
Correct
Incorrect
No continuity
Incorrect
Incorrect
• Short circuit of wire
harness
• Poor contact of coupler
• Faulty battery
Battery overcharges
• Faulty regulator/rectifier
• Faulty battery
• Poor contact of generator lead wire coupler
Others