2-18 PERIODIC MAINTENANCE
AIR BLEEDING THE COOLING CIRCUIT
• Add engine coolant up to the radiator inlet.
• Support the motorcycle upright.
• Slowly swing the motorcycle, right and left, to bleed the air
trapped in the cooling circuit.
• Add engine coolant up to the radiator inlet.
• Start up the engine and bleed air from the radiator inlet com-
pletely.
• Add engine coolant up to the radiator inlet.
• Repeat the above procedure until no air bleeds from the radi-
ator inlet.
• Loosen the air bleeding bolt
1
and check that the engine
coolant flows out.
• Close the air bleeding bolt securely.
• Close the radiator cap securely.
• After warming up and cooling down the engine several times,
add the engine coolant up to the full level of the reservoir.
Engine coolant capacity:
Engine side
: 2 400 ml (2.5/2.1 US/Imp qt)
Reservoir tank side : 250 ml (0.3/0.2 US/lmp qt)
Repeat the above procedure several times and make
sure that the radiator is filled with engine coolant up to
the reservoir full level.
Содержание 2006 gsxr 600
Страница 1: ...GSX R750 9 9 5 0 0 3 7 1 3 0 0 1 E ...
Страница 48: ...PERIODIC MAINTENANCE 2 31 ...
Страница 101: ...3 48 ENGINE TRANSMISSION PARTS LOCATION 1 Countershaft 2 Driveshaft ...
Страница 154: ...ENGINE 3 101 10 N m 1 0 kgf m 7 0 lb ft ...
Страница 324: ...7 20 COOLING AND LUBRICATION SYSTEM ENGINE LUBRICATION SYSTEM ...
Страница 325: ...COOLING AND LUBRICATION SYSTEM 7 21 ...
Страница 487: ...10 28 SERVICING INFORMATION SEAT LOCK CABLE ROUTING REAR FENDER INSTALLATION ...
Страница 521: ...Prepared by December 2005 Part No 99500 37130 01E Printed in Japan 524 ...
Страница 522: ...Printed in Japan K6 ...