Block Nr.  Length (bytes)  Description 

Read/Write 

Permission 

User data 

R / W 

Coin name 

R / W 

User data 

R / W 

Hopper dispense count 

R / W 

CheckSum A 

R / W 

Last payout: coins paid 

R / W 

CheckSum B 

R / W 

Last payout: coins unpaid 

R / W 

CheckSum C 

R / W 

Hopper life dispense count 

CheckSum D 

Black Box Recorder A 

Black Box Recorder B 

Black Box Recorder C 

Black Box Recorder D 

Table 10: EEProm Memory Description 

 
Storage temperature 

-20º C to +70º C 

Operating temperature 

0º C to +50ºC 

Storage humidity 

10% to 95% non-condensing 

Operating humidity 

10% to 75% RH 

General 

Keep coin exit clear from any obstacles 

Table 11: Environmental specifications 

Содержание Flow 18-ccTalk

Страница 1: ...low Hopper Model 18 ccTalk Product Manual Pre release Version 0 6 Februari 2011 Antonie van Leeuwenhoekstraat 9 3261 LT Oud Beijerland The Netherlands Phone 31 0 186 643333 Fax 31 0 186 643322 Email i...

Страница 2: ...ompatible with other popular hopper devices One configuration for euro coins 10ct to 2 euro coins Disk can reach a payout speed of 7 coins per second for euro s 3 different cup extensions Small medium...

Страница 3: ...Manual 18 ccTalk Version 0 6 Page 2 Attention Always turn power off before removing or installing the hopper in order to prevent any damage due to surge currents...

Страница 4: ...0020 16 23 16 00 18 99 2 10 3 20 18 0020 23 24 19 00 21 99 2 10 3 20 18 0020 24 25 22 00 28 49 2 10 3 20 18 0020 25 0 20 0 50 1 00 2 00 1 00 26 28 50 32 00 2 10 3 20 18 0020 26 Table 1 Payout discs Co...

Страница 5: ...anged with serial commands Unless you have an application requiring more than one Flow hopper on the serial bus it is strongly recommended you leave the address alone The default addresses for coin ac...

Страница 6: ...tting 3 2 Setting mode DIP Switch 5 and 6 are not used Switches 7 and 8 are used to select the type of ccTalk protocol See table below Mode Dip Switch 7 Dip Switch 8 ITA serial OFF OFF MC encrypted OF...

Страница 7: ...k slave device 8 bit addition checksum 5 1 ccTalk Connector Pinout Connector type Molex 8624 series or similar 10 pins 2x5 of 2 5mm Be careful with the pin numbering of the connector because not all m...

Страница 8: ...their own connectors Traditional machine wiring You can be seen that you need often 3 different cables 1 coin acceptor 1 note acceptor and 2 hoppers in order to build a system This is a quite expensi...

Страница 9: ...ities Each ccTalk hopper is equipped with a microcontroller implementing the ccTalk protocol You have to define exactly what the hopper should do when it receives a command If the hopper receives a pa...

Страница 10: ...215 block number data 1 data 2 data 8 Read data block 214 block nr data 1 data 8 ACK Write data block 192 none Lev Lo Request build code 172 none payout coins remaining Emergency stop 171 none Reques...

Страница 11: ...ormal ACK is received Device at address 3 is communicating ok If no response is received then check the hopper address by sending the ADDRESS POLL command Address Poll header 253 Command 00 00 01 FD 0...

Страница 12: ...all counter data in EEProm if data has changed this will take up to 90ms then send an ACK message to the host finally perform a software reset about 40 ms During software resetting can take up to 130m...

Страница 13: ...be sure to send this serial number along with the dispense command in order to start a payout See also Dispense Hopper coins header 167 Request Software Revision header 241 Command 03 00 01 F1 0B Resp...

Страница 14: ...commands Enter PIN number header 218 Command 03 04 01 DA 31 32 33 34 54 Response 01 00 03 00 FC The 4 bytes 31 32 33 34 transmitted along with the command are the PIN numbers Here PIN number 1234 is t...

Страница 15: ...age 62 98 0 2 N 0 127 V 12 6 V Connector address 0 0 N 3 3 3 Table 5 Hopper Variable Settings Motor current limit If the current through the motor is above the threshold level 3 3 A during 160 ms the...

Страница 16: ...t path blocked during idle flag is then set These flags can be cleared again with a Reset command but is set again 333ms after the Reset command due to the opto test during idle done 3x per second If...

Страница 17: ...aid Emergency Stop header 172 Command 03 00 01 AC 50 Response 01 01 03 00 00 FB The data byte in the response holds the number of unpaid coins since the dispensing was aborted by the Emergency Stop co...

Страница 18: ...uest Cipher Key command to randomize the security code from the hopper even more If dipswitch 8 is set to OFF ITA serial then the DISPENSE COINS command needs it s 3 byte serial number sent along with...

Страница 19: ...oin dispensing If it reached 0 the host software should check if the payment is completed or aborted by checking the coins paid and coins unpaid counters If a power reset occurred during a payout all...

Страница 20: ...to check if the high level sensor is present Request Hopper dispense count header 168 Command 03 00 01 A8 54 Response 01 03 03 00 2E 02 00 C9 The 3 data bytes 2E 02 00 represent the 3 byte total dispe...

Страница 21: ...Command 03 09 01 A7 63 D9 2A 95 BA D4 35 82 03 09 Response 01 01 03 00 01 FA The host sends the encrypted security code 63 D9 2A 95 BA D4 35 82 together with the number of coins to pay 03 If the hopp...

Страница 22: ...tVariableSettings SER_NR HOPPER_ADDRESSx Optional the following items may be retrieved Hopper x ManufacturerID Hopper x ProdCode Hopper x SoftwareRev Hopper x CommsRev Hopper x HopperCoin Hopper x Bui...

Страница 23: ...per status each 100ms for real time display of count values HopperCounters RequestHopperStatus HopperAddress update status counters while HopperCounters NrCoinsRemaining 0 Verify Dispense procedure ma...

Страница 24: ...hopper is above the POWER_FAIL_TRESHOLD level the hopper will start an anti jam operation by reversing and restarting the hopper motor If the motor current is greater than 3 3A during 160ms the motor...

Страница 25: ...ameter Description Value Units Brate Serial communication speed 9600 baud Trxout Receive data timeout 25 ms TPinit Power up initialisation time 630 ms TSinit Software reset init time 40 ms PWMFreq Mot...

Страница 26: ...out coins unpaid R W 2 1 CheckSum C R W 3 3 Hopper life dispense count R 3 1 CheckSum D R 3 1 Black Box Recorder A R 3 1 Black Box Recorder B R 3 1 Black Box Recorder C R 3 1 Black Box Recorder D R Ta...

Страница 27: ...pply when the original invoice with model number and purchase date together with the defective product is presented within the warranty period 2 Suzo is under no obligation to perform warranty when in...

Страница 28: ...Manual 18 ccTalk Version 0 6 Page 27 10 Dimensions 10 1 General dimensions 10 2 Medium and large Extensions...

Страница 29: ...Version 0 6 Page 28 11 Revision History Revision Date Comment By 0 1 09 Jul 2010 Pre release E S 0 4 29 Sept 2010 Drawings and exploded views M M 0 5 29 Nov 2010 Update manual M M 0 6 16 Feb 2011 Upd...

Страница 30: ...ded only to assist the reader in the use of this product and therefore Suzo International shall not be held liable for any loss or damage whatsoever arising from the use of any information or particul...

Отзывы: