LAMBDA DG-4 & DG-5 OPERATION MANUAL – REV.
3.05C
(
20150414
)
65
APPENDIX E.
EXTERNAL-CONTROL COMMAND REFERENCE
This appendix provides a complete list of remote control commands and return values.
Table E-1. Filter-selection command reference.
Byte Value
Keyboard Entry
Positioning
Light Beam
DG-4
DG-5
Dec.
Hex.
Binary Alt-keypad
entry
Ctrl-
char.
ASCII
def./-
char.
Nomi-
nal Pos.
Index
Filter
Attenua-
tion
Filter
Attenua-
tion
Interference Movement
…
0 00
00000000 Alt-0000 ^@ (NUL)
0 0 0% 0 0%
Blocked
(shutter
closed)
1 01
00000001 Alt-0001 ^A (SOH)
1 1
1
2 02
00000010 Alt-0002 ^B (STX)
2 2
2
3 03
00000011 Alt-0003 ^C (ETX)
3 3
3
4 04
00000100 Alt-0004 ^D (EOT)
4 4
100%
4
5 05
00000101 Alt-0005 ^E (ENQ)
5 1
5
100%
6 06
00000110 Alt-0006 ^F (ACK)
6 2
1
7 07
00000111 Alt-0007 ^G (BEL)
7 3
2
8 08
00001000 Alt-0008 ^H
(BS)
8 4
50%
3
9 09
00001001 Alt-0009 ^I
(HT)
9 1
4
10 0A
00001010 Alt-0010 ^J
(LF)
10 2
5
50%
11 0B
00001011 Alt-0011 ^K
(VT)
11 3
1
12 0C
00001100 Alt-0012 ^L
(FF)
12 4
33%
2
13 0D
00001101 Alt-0013 ^M
(CR)
13
3
14 0E
00001110 Alt-0014 ^N
(SO)
14
4
15 0F
00001111 Alt-0015 ^O
(SI)
15
5
33%
Selected filter
blockage:
None, ½, or 2/3
… on
Command
(Notes 1 & 2)
16 10
00010000 Alt-0016 ^P (DLE)
0 0 0% 0 0%
Blocked
(shutter
closed)
17 11
00010001 Alt-0017 ^Q (DC1)
1 1
1
18 12
00010010 Alt-0018 ^R (DC2)
2 2
2
19 13
00010011 Alt-0019 ^S (DC3)
3 3
3
20 14
00010100 Alt-0020 ^T (DC4)
4 4
100%
4
21 15
00010101 Alt-0021 ^U (NAK)
5 1
5
100%
22 16
00010110 Alt-0022 ^V (SYN)
6 2
1
23 17
00010111 Alt-0023 ^W (ETB)
7 3
2
24 18
00011000 Alt-0024 ^X (CAN)
8 4
50%
3
25 19
00011001 Alt-0025 ^Y
(EM)
9 1
4
26 1A
00011010 Alt-0026 ^Z (SUB)
10 2
5
50%
27 1B
00011011 Alt-0027 ^[ (ESC)
11 3
1
28 1C
00011100 Alt-0028 ^\
(FS)
12 4
33%
2
29 1D
00011101 Alt-0029 ^]
(GS)
13
3
30 1E
00011110 Alt-0030 ^^
(RS)
14
4
31 1F
00011111 Alt-0031 ^_
(US)
15
5
33%
Selected filter
blockage:
None, ½, or 2/3
… on
Trigger
(Notes 1, 2, &
3)
NOTES:
1.
Nominal Filter Position (Bits 0 – 3): Value range 0 through 15, and with Bit 4 = 1, 16 through 31.
2.
Move on Command or Trigger (Bit 4): 0 (on command (i.e., immediately) or 1 (by trigger (see Note 3)).
3.
“On trigger” means the light beam moves only on Strobe (strobe line), Synch (video synch), or Synch Gated
by Strobe.
Содержание Lambda DG-4
Страница 3: ......
Страница 4: ......
Страница 9: ......
Страница 14: ......
Страница 18: ...LAMBDA DG 4 DG 5 OPERATION MANUAL REV 3 05C 20150414 4 This page intentionally blank ...
Страница 26: ...LAMBDA DG 4 DG 5 OPERATION MANUAL REV 3 05C 20150414 12 This page intentionally blank ...
Страница 48: ...LAMBDA DG 4 DG 5 OPERATION MANUAL REV 3 05C 20150414 34 This page intentionally blank ...
Страница 63: ...LAMBDA DG 4 DG 5 OPERATION MANUAL REV 3 05C 20150414 49 ...
Страница 64: ......
Страница 70: ...LAMBDA DG 4 DG 5 OPERATION MANUAL REV 3 05C 20150414 56 This page intentionally blank ...
Страница 72: ...LAMBDA DG 4 DG 5 OPERATION MANUAL REV 3 05C 20150414 58 This page intentionally blank ...
Страница 82: ...LAMBDA DG 4 DG 5 OPERATION MANUAL REV 3 05C 20150414 68 This page intentionally blank ...
Страница 86: ...LAMBDA DG 4 DG 5 OPERATION MANUAL REV 3 05C 20150414 72 NOTES ...