ALARM – SHREDDER MOTOR - FUSE TRIPPED
Follow the instructions on the screen:
Reset the fuse inside the electrical cabinet.
Inspection of the shredder is needed. Problem can be caused by food
waste material getting stuck in the shredder. If necessary run the
shredder in reverse and thereby loosen any material that is stuck.
Problem can also be caused by a faulty inverter.
Note that this ALARM needs to be acknowledged in the ALARM list in order to turn off the Alarm
Indicator which is visible in the left hand upper corner on all screens.
Use the ALARM button to go to alarm log menu.
From this alarm screen, it is possible to navigate to the
‘manual run shredder’ screen pressing the symbol with
the infeed and two arrows on the alarm screens.
Use the back and forward arrow trying to loosen the
blockage in the shredder.
Normally if there is a blockage of the shredder, the alarm that goes off is the ‘ALARM SHREDDER - Shredder
has automatically reversed 2 times but is still unable to run’ see 10.13. If there is an alarm that the fuse for
the shredder motor has tripped the settings of the function of the infeed reversing two times may need
adjusting, see above.
If the shredder has been cleared and the alarm comes back check the shredder’s drive belt, see
Содержание BIGHANNA T120
Страница 8: ......
Страница 28: ......
Страница 32: ......
Страница 80: ...5 3 1 START UP SCHEDULE MODEL T60 RESTAURANT WASTE...
Страница 81: ......
Страница 82: ...5 3 2 START UP SCHEDULE MODEL T120 RESTAURANT WASTE...
Страница 83: ......
Страница 84: ...5 3 3 START UP SCHEDULE MODEL T240 RESTAURANT WASTE...
Страница 85: ......
Страница 86: ......
Страница 94: ......
Страница 114: ......