BATTERY SYSTEM

 

Battery Type 

Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid 

Typical Recharge Time 

8-hours to 90% capacity from a full load discharge 

Typical Battery Life 

3 to 5 years.  Environmental factors do affect battery life.  High temperatures, poor utility power, and 
frequent, short duration discharges  have  a  negative  impact  on  battery  life. 

                                SURGE PROTECTION AND FILTERING

 

Voltage Protection Rating (VPR) 

 

330V Line-Neutral 

Noise Filter 

 

Normal Mode 

Battery : > 30dB 130kHz 

 50MHz 

Surge Only : > 30dB 120kHz 

 50MHz 

 

Common Mode 

Battery : 

> 10dB 300kHz 

 50MHz 

> 20dB 1.3MHz 

 50MHz 

Surge Only : 

> 10dB 280kHz 

 50MHz 

> 20dB 2.1MHz 

 50MHz 

Audible Noise at 1 m (3 ft.) 

<30 dBA 

ENVIRONMENTAL

 

Operating Temperature 

                     0 to 40°C (+32 to +104°F) 

Operating Elevation 

                    0 to 3000m (0 to +10,000 ft) 

Operating/Storage Humidity 

                    0 - 95% Non-Condensing 

Storage Temperature 

                    -15 to +45°C (+5 to +113°F) 

Storage Elevation 

                      0 to 15,000m (0 to +50,000 ft) 

    PHYSICAL

 

Size - Net 
L X W X H 

                                                 10.75 x 19 x 3.5" 
 

 

 

Weight - Net 

                                                           32 lbs. 
 
 

 

 

Size - Shipping 
L X W X H 

                                                    21.5 x 6.5 x 6.5" 
 

 

 

Weight - Shipping 

                                                             35 lbs 
 

 

 
 

 

Содержание UPS-1000-Li-2

Страница 1: ...UPS 1000 Li 2 UserManual UPS 1000 Li 2 User Manual 2019 AMETEK Electronic Systms Protecion Technical Support 1 800 645 9721 surgex com UM UPS 1000 Li 2 Rev A...

Страница 2: ...UPS 1000 Li 2 UserManual 2018 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 surgex com...

Страница 3: ...IES 3 3 CONNECTING THE UPS 1000 LI 2 TO AN AC SOURCE 3 4 CHECKING THE SITE WIRING FAULT 3 5 CHARGING THE BATTERY 3 6 CONNECTING YOUR EQUIPMENT 4 7 USB COMMUNICATION PORT CONNECTION OPTIONAL 4 8 POWER...

Страница 4: ...or adapter plugs or surge protectors CAUTION To reduce the risk of fire connect only to a utility powered circuit provided with 20 amperes maximum branch circuit over current protection in accordance...

Страница 5: ...e as 20 40 60 80 100 When the amount of load attached to the UPS 1000 Li 2 exceeds 110 of its power rating the Overload icon will flash Off and On all of the LEDs in the Load Level Bar Graph will be i...

Страница 6: ...llation 3 Connecting the UPS 1000 Li 2 to an AC Source CAUTION To reduce the risk of fire connect only to a utility powered circuit provided with 20 amperes maximum branch circuit over current protect...

Страница 7: ...onfigured ConnectingtotheCommunications Port is optional The UPS 1000 Li 2 works properly without this connection 8 POWER MONITORING SOFTWARE This productsupports Power Monitoring Software Please go t...

Страница 8: ...orma self test onstart up 7 Alarms ONBATTERY When the UPS 1000 Li 2 is operating on the batteries the AC normal icon will extinguish the On Battery icon will illuminate the LCD will display the estima...

Страница 9: ...nction The unit does not provide expectedruntime Charge the batteries for 8 hours and retest If the runtime is still less than expected the batteries may need to be replaced The AC normal icon is illu...

Страница 10: ...properly The batteries contain lead and pose a hazard to the environment and human health if not disposed of properly Refer to local codes for proper disposal requirements CAUTION The battery system...

Страница 11: ...2 3 Unplug the UPS 1000 Li 2 sAC power cord from theAC wall outlet 4 Unplug the equipment from the output receptacles of the UPS 1000 Li 2 5 Unplug the computer interface cable from the rear panel of...

Страница 12: ...wer at 136V or lower InputProtection ResettableCircuitBreaker OUTPUTNON BATTERYOPERATION VoltageRange 104 140VAC VoltageRegulation 120VAC 13 3 16 7 FrequencyRange 60Hz 54 66Hz Efficiency LineMode 96 F...

Страница 13: ...life SURGE PROTECTIONAND FILTERING Voltage Protection Rating VPR 330V Line Neutral NoiseFilter Normal Mode Battery 30dB 130kHz 50MHz Surge Only 30dB 120kHz 50MHz Common Mode Battery 10dB 300kHz 50MHz...

Отзывы: