Error Message
Explanation
Number of disks found = y,
needed = z
The number of disks found (y) does not match the number of
disks configured for. The number of disks needed (z) is
required.
Disk x not installed!
A disk drive (x) is not installed or is unable to be accessed.
Disk x previously removed!
A disk (x ) was removed due to a failed disk or by the
operator.
Too many RAID members failed!
The minimum number of disks required for the RAID
configuration failed to initialize.
RAID not configured!
RAID can not be configured due to too few good disks
available or no RAID configuration has been performed.
Disk x is too small!
A disk capacity being added to an existing RAID
configuration is less than the configured disks. To add a disk
to an existing configuration the disk must be the equal size or
greater.
Disk x format ERROR!
Disk (x) failed during the format. Possible bad disk.
Init RAID5 ERROR!
The RAID 5 initialization failed. Possible bad disk. Use
Disk Check to identify faulty disk.
Disk x add ERROR!
Disk (x) being added failed. Possible bad disk. Use Disk
Check to identify faulty disk.
Parity ERROR: blk ? !!
A parity byte was unable to be read/write. Blk ? is the block
(sector) on the disks that failed. Possible bad disk.
RAID 5 Check ERROR!
The R5 Check function failed. Possible wrong RAID
configuration or not initialized (Init RAID5).
Param vendor ID ERROR!
The information in NVRAM has been erased. The
configuration is lost.
Param checksum ERROR!
The information in NVRAM has been erased. The
configuration is lost.
SCSI chip ERROR!
The SCSI interface of the
SurfRAID LC12
controller is
faulty.
Testing Serial Connection…
Fail
The RS-232, M odem, or UPS port is faulty.
Do_IDE_Cmd: wait DRQ
The IDE interface is waiting for DRQ signal to go off in
command phase.
Do_IDE_Cmd ERROR ? !
An error (?) occurred in IDE interface. Use Disk Check to
identify faulty disk channel.
IDE_ISR: wait Master Int
IDE interface is waiting for an interrupt from a disk.
IDE_ISR: wait IDE Busy off
IDE interface is waiting for disk to be free.
IDE_ISR: status ?
IDE disk drive current status (?)
IDE_ISR: wait DRQ
To wait for disk drive to turn off DRQ in Interrupt phase.
IDE_ISR: DRQ ON
Indicates DRQ is not free in Interrupt phase.
DISK: status ?, error: ? !!
The status (status ?) and error (error: ?) returned by the disk
based on the ATA-2 Specification.
DISK: #X type=?, blkno=?,
resid=?
The disk (x) failed to respond to a request by the controller
(type=?). The block number (blkno=?) where the request
failed. The remaining sectors (resid=?)