APPENDIX C
4/2-style Format with Sur-Gard Schedule 3A
DVACS Compatible
Updated for Version 4 Decoding
A section of the more than 2000 zones available on the MLR1 Receiver has been reserved for 4/2 Digital Dialer
Format-style printer and computer output such. The following table shows the zones reserved for 4/2-type output:
Printer
Computer
Zone
Message
Zone
Byte
01-08
---- Alm/Rst Zn#01-08
01-08
50
09
---- Alm/Rst Zn#09
09
51
10-17
Fire! Alm/Rst Zn#10-17
10-17
0C
18-1F
Fire! Alm/Rst Zn#18-1F
18-1F
0D
20-27
Panic Alm/Rst Zn#20-27
20-27
0E
28-2F
Panic Alm/Rst Zn#28-2F
28-2F
0F
30-37
Inst. Alm/Rst Zn#30-37
30-37
10
38-3F
Inst. Alm/Rst Zn#38-3F
38-3F
11
40-47
Mtion Alm/Rst Zn#40-47
40-47
12
48-4F
Mtion Alm/Rst Zn#48-4F
48-4F
13
50-57
24Hrs Alm/Rst Zn#50-57
50-57
14
58-5F
24Hrs Alm/Rst Zn#58-5F
58-5F
15
60-67
Tampr Alm/Rst Zn#60-67
60-67
16
68-6F
Tampr Alm/Rst Zn#68-6F
68-6F
17
70-77
Delay Alm/Rst Zn#70-77
70-77
18
78-7F
Delay Alm/Rst Zn#78-7F
78-7F
19
80-87
Optn1 Alm/Rst Zn#80-87
80-87
1A
88-8F
Optn1 Alm/Rst Zn#88-8F
88-8F
1B
90-97
Optn2 Alm/Rst Zn#90-97
90-97
1C
98-9F
Optn2 Alm/Rst Zn#98-9F
98-9F
1D
A0-A7
Optn3 Alm/Rst Zn#A0-A7
A0-A7
1E
A8-AF
Optn3 Alm/Rst Zn#A8-AF
A8-AF
1F
B0-B7
Fire: Alm/Rst Zn#B0-B7
B0-B7
2E
B8-BF
Fire: Alm/Rst Zn#B8-BF
B8-BF
2F
C0-C7
Hpres Trb/Rst Zn#C0-C7
C0-C7
34
C8-CF
Lpres Trb/Rst Zn#C8-CF
C8-CF
35
D0-D7
Valve Trb/Rst Zn#D0-D7
D0-D7
36
D8-DF
Valve Trb/Rst Zn#D8-DF
D8-DF
37
E0-E7
XXXXX Trb/Rst Zn#E0-E7
E0-E7
6C
E8-EF
XXXXX Trb/Rst Zn#E8-EF
E8-EF
6B
F0-FF
Do Not Use
XXXXX represents variable messages; refer
to MLR1 Library.
The following are outputs for bypasses and clearing
bypasses
Printer
Computer
Zone
Message
Zone
Byte
01-08
---- Byp/Unb Zn#01-08
01-08
D0
09
---- Byp/Unb Zn#09
09
D1
10-17
Fire! Byp/Unb Zn#10-17
10-17
8C
18-1F
Fire! Byp/Unb Zn#18-1F
18-1F
8D
20-27
Panic Byp/Unb Zn#20-27
20-27
8E
28-2F
Panic Byp/Unb Zn#28-2F
28-2F
8F
30-37
Inst. Byp/Unb Zn#30-37
30-37
90
38-3F
Inst. Byp/Unb Zn#38-3F
38-3F
91
40-47
Mtion Byp/Unb Zn#40-47
40-47
92
48-4F
Mtion Byp/Unb Zn#48-4F
48-4F
93
50-57
24Hrs Byp/Unb Zn#50-57
50-57
94
58-5F
24Hrs Byp/Unb Zn#58-5F
58-5F
95
60-67
Tampr Byp/Unb Zn#60-67
60-67
96
68-6F
Tampr Byp/Unb Zn#68-6F
68-6F
97
70-77
Delay Byp/Unb Zn#70-77
70-77
98
78-7F
Delay Byp/Unb Zn#78-7F
78-7F
99
80-87
Optn1 Byp/Unb Zn#80-87
80-87
9A
88-8F
Optn1 Byp/Unb Zn#88-8F
88-8F
9B
90-97
Optn2 Byp/Unb Zn#90-97
90-97
9C
98-9F
Optn2 Byp/Unb Zn#98-9F
98-9F
9D
A0-A7
Optn3 Byp/Unb Zn#A0-A7
A0-A7
9E
A8-AF
Optn3 Byp/Unb Zn#A8-AF
A8-AF
9F
B0-B7
Fire: Byp/Unb Zn#B0-B7
B0-B7
9E
B8-BF
Fire: Byp/Unb Zn#B8-BF
B8-BF
9F
C0-C7
Hpres Byp/Unb Zn#C0-C7
C0-C7
94
C8-CF
Lpres Byp/Unb Zn#C8-CF
C8-CF
95
D0-D7
Valve Byp/Unb Zn#D0-D7
D0-D7
96
D8-DF
Other Byp/Unb Zn#D8-DF
D8-DF•
97
E0-E7
Zn#E0-E7 Bypass/Unbyp.
E0-E7
9C
E8-EF
Zn#E8-EF Bypass/Unbyp.•• E8-EF
9B
F0-FF
Do Not Use
Notes:
•
Zone D8 is the default setting for Common Bypass.
•• Individual messages per zone are standard. Refer
to DVACS Line Card Alarm Decoding Version 4 for
further information.
The printer messages for zones 10 through AF can
be changed to “_____” followed by “Alm/Rst” or
“Byp/Unb” and “Zn#”.
firealarmresources.com