15
PROGRAMMABLE OUTPUT TYPES
The operation of the output terminal PGM OUT may be programmed. Enter the number of the desired function in Mode
22 Addresses [035] through [037].
01 Kiss-off Signal
When programmed as [01], the output will be activated for 3 seconds following the confirmation (kissoff) signal
indicating that messages transmitted from the control panel have been received at the monitoring station.
02 DVACS Communication Problem
If the system is unsuccessful in communicating with the monitoring station, a Fail to Communicate (Line Cut)
trouble will be generated. If a later attempt to communicate is successful, the trouble condition will be cleared.
03 Courtesy Light
This output option is designed to be used with a light that comes on when the Entry or Exit Delay is activated.
For example, a light in the hallway leading to the Keypad would come on when the entry door is opened. When
the Entry Delay begins, the output will be activated for approximately 2 minutes. The output will remain active
even if the Entry Delay expires or an alarm is generated.
04 Follow Bell / Siren
When programmed as [04], the output is activated whenever the BELL output is activated.
05 Follow Group A Armed / Disarmed Status
When programmed as [05], the output will be “on” whenever Group A is armed, and the output will be “off”
whenever Group A is disarmed.
06 Follow Group B Armed / Disarmed Status
When programmed as [06], the output will be “on” whenever Group B is armed, and the output will be “off”
whenever Group B is disarmed.
07 Follow Group C Armed / Disarmed Status
When programmed as [07], the output will be “on” whenever Group C is armed, and the output will be “off”
whenever Group C is disarmed.
08 Follow Group D Armed / Disarmed Status
When programmed as [08], the output will be “on” whenever Group D is armed, and the output will be “off”
whenever Group D is disarmed.
09 Follow Group A Ready Status
When programmed as [09], the output will be “on” whenever Group A is disarmed and in the “ready” state; the
output will be “off” whenever Group A is armed or otherwise not in the “ready” state. The output will be pulsed
during the Exit Delay Time for Group A.
10 Follow Group B Ready Status
When programmed as [10], the output will be “on” whenever Group B is disarmed and in the “ready” state; the
output will be “off” whenever Group B is armed or otherwise not in the “ready” state. The output will be pulsed
during the Exit Delay Time for Group B.
11 Follow Group C Ready Status
When programmed as [11], the output will be “on” whenever Group C is disarmed and in the “ready” state; the
output will be “off” whenever Group C is armed or otherwise not in the “ready” state. The output will be pulsed
during the Exit Delay Time for Group C.
12 Follow Group D Ready Status
When programmed as [12], the output will be “on” whenever Group D is disarmed and in the “ready” state; the
output will be “off” whenever Group D is armed or otherwise not in the “ready” state. The output will be pulsed
during the Exit Delay Time for Group D.
13 Utility Output (Mode 04 or 05) No Code
When programmed as [13], the output will be activated when Mode 04 or Mode 05 is entered; an Access Code
will not be required to activate the output. Refer to the Instruction Manual for more information.
14 Utility Output (Mode 04 or 05) Any Code
When programmed as [14], the output will be activated when Mode 04 or Mode 05 is entered and any valid
Access Code is keyed in. Refer to the Instruction Manual for more information.
15 Utility Output (Mode 04 or 05) Keypad Control
When programmed as [15], the output will be activated when the [4] and [5] keys are pressed simultaneously.
Refer to the Instruction Manual for more information.
16 Utility Output (Mode 04 or 05), Group A Code
When programmed as [16], the output will be activated when Mode 04 or Mode 05 is entered and any valid
Access Code assigned to Group A is keyed in.