Installer Messages Function Byte
Up to 16 messages can be displayed at the monitoring station to indicate that the Installer is on the premises or
that service is being performed. The Installer Messages are displayed by entering Mode 29; when Mode 29 is
entered and a message is selected, the system transmits a reporting code to the monitoring station.
The function byte determines the message to be printed at the monitoring station. The default setting is “1F”; the
message printed at the central station will be:
Optn3 AlmZnA8 (AF) for Installer Messages 1 through 8
Optn3 RstZnA8 (AF) for Installer Messages 9 through 16
To change the Installer Messages Function Byte, enter a 2-digit hexadecimal code in this Address. Refer to
Appendix C: 4/2 Format with Sur-Gard Schedule 3A for a list of the messages that will be printed or displayed with
each 2-digit hexadecimal code.
[725] - [731]
For Future Use
[732]
Alarm on Exit Code
The Alarm on Exit Code will be transmitted if a zone is in alarm or in a trouble condition during the Exit Delay time.
The Alarm on Exit Code only be transmitted to report zone alarm or zone trouble conditions; the code will not be
transmitted for other trouble conditions.
[733]
For Future Use
[734]
Test Mode Function Byte
When Mode 25 is used to test the system, the system will report that testing is underway to the central station.
The Test Mode Function Byte determines which printer message will be used when testing is reported.
The default setting is “6C”; the message printed at the central station will be:
Alm Zn E0 for “testing started” indication
Rst Zn E0 for “testing finished” indication
To change the Test Mode Function Byte, enter a 2-digit hexadecimal code in this Address. Refer to Appendix C: 4/
2 Format with Sur-Gard Schedule 3A for a list of the messages that will be printed or displayed with each 2-digit
hexadecimal code.
[735]
Number of Zones Not Tested Function Byte
When testing using Mode 25 is completed, the system will report how many zones were not tested. The Number of
Zones Not Tested Function Byte determines which printer message will be used when the number of untested
zones is reported.
The default setting is “00”; the message printed at the central station will be:
Burg1 RstZnXX where XX represents the number of untested zones
To change the Number of Zones Not Tested Function Byte, enter a 2-digit hexadecimal code in this Address.
Refer to Appendix C: 4/2 Format with Sur-Gard Schedule 3A for a list of the messages that will be printed or
displayed with each 2-digit hexadecimal code.
[736] - [743]
For Future Use
[744]
Cancel Alarm Code
The Cancel Alarm Code is transmitted when the user cancels an alarm using the [
∗
][7] Cancel Alarm function.
When an alarm is cancelled, the 2-digit Alarm Cancel Code is transmitted, followed by the user code to indicate
which user cancelled the alarm.
[745] - [800]
For Future Use
[801]
No Restoral Reports for Zones 1 - 8
Alarm restoral reports can be disabled for each individual zone. When this Address is entered, the Zone Lights will
indicate which zones will generate alarm restoral reports:
• if a Zone Light is ON, no alarm restoral report will be generated
• if a Zone Light is OFF, an alarm restoral report will be generated
To turn Zone Lights ON or OFF, press the number key for the desired zone.
Programming Mode 20