4
2. Technical Specification
Executing Standard
CMC GB/T 7724-2008
《
Electronic Weighing Meter
》
PRC National Standard.
OMIL R76: 2006
《
Non-automatic Weighing Instruments
》
International Recommendation.
Accuracy Grade: III.
Verification Accuracy: 0.03%.
Static Weighing Accuracy: 0.2%~0.5%.
Display
5 Red LED digital tubes for English character and digit display.
Weight Display Range: -9,999~+99,999.
Scale Capacity: Setting Range 1~99,999.
Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
Display Resolution: 1/50,000.
Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
Display Refreshing Time: Setting Range 0.01~1.00s.
Keypad
4-key keypad for Menu&Shortcut mode operation.
Weighing Signal Interface
Excitation Voltage / Max. Current 1: DC5V/120mA for 8-
350Ω
loadcells.
Excitation Voltage / Max. Current 2: DC12V/100mA for weighing transmitter.
Optional weighing input
signal mV, V and mA for connecting ‘
【
mV
】
Output Type Loadcell’, ‘
【
V
】
Voltage Output Type Weighing Transmitter’ and ‘
【
mA
】
Current Output Type Weighing
Transmitter’.
【
mV
】
Signal Input Range: 0~19.5mV [Output Sensitivity of Loadcell: 1.0~3.5mV/V].
【
V
】
Signal Input Range: 0~2.5V, 0~5V, 0~10V.
【
mA
】
Signal Input Range: 0~20mA.
24-bit
∑
-
△
ADC with internal resolution 1/1,000,000.
Sampling Frequency: 1280Hz.
Special Anti-vibration Digital Filtering Algorithm for precise weighing, stable display and rapid
response.
Zero Drift: ±0.1
μ
V/
℃
RTI (Relative to Input).
Gain Drift: ±5ppm/
℃
.
Non-linearity: 0.005%FS.
Switch&Analog Signal Interface
1 Definable normally open switch input [DI].
2 Relay switches with normally open and normally closed contacts for outputting upper limit and
lower limit alarm signals.
Contact Capacity of Relay Switch: AC250V/DC24V, 1A.