Supmeter BST106-B60S(L) Скачать руководство пользователя страница 39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changsha Supmeter Technological Co., Ltd. 

Address: Building A6, Lugu International Industrial Park, 

Changsha, 410205, China 

Tel: +86 731 85115100 
Fax: +86 731 85158100 
Website: www.supmeter.com 
E-mail: [email protected] 

 

CPC16/042376 

2014F108-43 

Содержание BST106-B60S(L)

Страница 1: ...6 B60S L Weighing Force Measuring Controller Weight Force Display Peak Value Detection Display Holding Setpoint DO Output AO Digit Transmission Operation Manual V5 0 Changsha Supmeter Technological Co...

Страница 2: ...d A D conversion module with 1 1 000 000 internal resolution and sampling frequency 1280Hz Special anti vibration digital filtering algorithm for ensuring the weighing stability and accuracy when ther...

Страница 3: ...tpoint Parameters SEtP 19 6 2 4 Communication Parameters SErP 21 6 2 5 Display Parameters dISP 22 6 2 6 A Sample of Parameter Setting 23 6 3 F2 CAL SYSTEM CALIBRATION 24 6 3 1 Zero Calibration ZEro 24...

Страница 4: ...y with the ground resistance being less than 4 Cable Laying Weighing signal analog signal and communication signal cables should be laid in pipes and do not lay them together with power cables Power S...

Страница 5: ...mA for 8 350 loadcells Excitation Voltage Max Current 2 DC12V 100mA for weighing transmitter Optional weighing input signal mV V and mA for connecting mV Output Type Loadcell V Voltage Output Type Wei...

Страница 6: ...t IPC PLC and LED Remote Display Operating Specification Operating Voltage DC24V 20 Max Power Consumption 5W Outline Size 107 60 100mm W H D Panel Cut out Size 94 47mm W H Operating Temperature 25 to...

Страница 7: ...ode A Parameter 904 0 dE Default Set Key Name Description Key locking Key unlocking SET Setpoint parameters setting ZERO 0 ZEro Zero Calibration with Power down Protection and Clearing Tare Weight ZEr...

Страница 8: ...g ZERO 0 Zero Calibration with Power down Protection and Clearing Tare Weight The controller will switch to Gross Weight display TARE T Manual Tare with Power down Protection The controller will switc...

Страница 9: ...ure Replace the ADC module oV Ad Over ADC Range Weighing signal exceeds A D conversion range 1 Check if the loadcell is connected 2 Check if the capacity of loadcell is too small 3 Check if the loadin...

Страница 10: ...1 Installation Outline Size W H D mm Front Panel Size W H mm Box Body Size W H mm Panel Cut out Size W H mm 107 60 100 107 60 93 46 94 47 Installation Mode 94 47 Panel Cut out Size Outline Size Front...

Страница 11: ...ll be unstable Select weighing signal via setting Switch DIP1 DIP2 and Parameter 111 Weighing Signal Type Weighing Signal 0 19 5mV 0 20mA 0 2 5V 0 5V 0 10V DIP1 in rear panel Set Left mV Right mA Midd...

Страница 12: ...eld Ground 8 DI1 Switch Signal Input 1 POWER DC24V 20 Power Input Port 9 DC DC Input 10 DC DC Input The metal shell should be grounded directly For separating the controller from the interference of t...

Страница 13: ...ort Application Mode Parameter 212 AP AP 1 HL AP 2 HH AP 3 LL AP 4 SEC DO1 203 SET1 203 SET1 203 SET1 SET1 203 SET2 DO2 203 SET2 203 SET2 203 SET2 203 SET1 203 SET2 Connection Power on Zero Calibratio...

Страница 14: ...ibration 19 5EV mV Data Calibration Input Parameters Total Capacity and Output Sensitivity of Loadcell 20EA mA Data Calibration Input Parameters Capacity Zero Value and Full Value of Current Output Ty...

Страница 15: ...weighing test equipment to adjust the mV weighing signal interface for normalizing Span Coefficient to 1 mA V Exfactory Span Adjustment Use precision current source to adjust the mA V weighing signal...

Страница 16: ...cell Capacity Loadcell Quantity Self weight of Load Receptor 103 dV 1 500 1 Scale Division 1 2 5 10 20 50 100 200 500 104 ZE 99999 99999 0 Zero Value Only for query 105 SP 0 1 0000 Span Coefficient Ma...

Страница 17: ...4Hz 8 1 0Hz 9 0 7Hz Filter1 s 101 Digit Set Set Value Anti Vibration Grade 0 Medium 1 High 110 Sb 1 128 1 Weight Display Smooth Filter2 The bigger set value of Filter2 will make the weight display va...

Страница 18: ...within this range Zero Fine Adjustment will be valid Suggestion Set value Scale Capacity 4 124 dZ 0 99 5 Range of Displaying Zero When the absolute value of weight is within this range the weight dis...

Страница 19: ...90000 99999 Correction Point s AD Value 1 10 AD Value detected via Segmenting Correction Demand d1 d2 d10 Only for query 151 152 153 154 155 156 157 158 159 160 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA C10 0 01...

Страница 20: ...205 dL 0 1 5 0 0 5 DO Bounce back Delay Time s Used for avoiding that the DO alarm switch turns on and off frequently with its related real time data being at the critical point Min Interval Time for...

Страница 21: ...t without Power down Protection and without Clearing Tare Weight 1 ZEro Zero Calibration with Power down Protection and Clearing Tare Weight 2 tArE Manual Tare without Power down Protection 3 rStr Cle...

Страница 22: ...inuous Sending ASCII 807 dA 0 3 2 Data for Continuous Sending Mode 0 groS Gross Weight 1 nEt Net Weight 2 dISP Displayed Characters 3 PnEt Net Weight Peak Value 808 SF 0 9 2 Continuous Sending Frequen...

Страница 23: ...y keypad operation in one minute and it s not in the processes of F2 System Calibration F6 Factory Adjustment the controller will lock the keypad and return to Main Display Interface automatically 903...

Страница 24: ...23 6 2 6 A Sample of Parameter Setting Modify the parameter 102 Scale Capacity Moving cursor Digit input Main Display Interface Exit Save M M...

Страница 25: ...atically 6 3 1 Zero Calibration ZEro Do Zero Calibration without loading on the weigher and save the new Zero Value Exit Save M Main Display Interface M 104 Zero Value E XX XX Voltage Value mV U XX XX...

Страница 26: ...on Note Total Capacity of Loadcells Loadcell Capacity Loadcell Number Voltage Ratio Excitation Voltage on the terminal of controller Excitation Voltage on the terminal of loadcells The rated excitatio...

Страница 27: ...o access to get the specification parameter values for Data Calibration then it s necessary to do Load Calibration Prompt Message EA mA Data Calibration Main Display Interface M Input Total Capacity o...

Страница 28: ...n parameter values for Data Calibration then it s necessary to do Load Calibration Prompt Message 2 5V 2 5V Data Calibration 5V 5V Data Calibration 10V 10V Data Calibration Main Display Interface M In...

Страница 29: ...weight on the weigher to correct Span Coefficient further for higher weighing accuracy The loading weight should be bigger than 50 of Scale Capacity value Exit Save M Main Display Interface M Input C...

Страница 30: ...rrection Points to get Span Correction Ratio of 10 linearity segments for higher weighing accuracy Main Display Interface M Loading Correction Point s Loading Weight 1 on the weigher Display AD Value...

Страница 31: ...ameter 161 is used for opening closing the function of Segmenting Weight Calculation Display AD Value After AD Value is stable press 152 Span Correction Ratio 2 M Save Save Loading Correction Point s...

Страница 32: ...oPEn 6 4 2 Key locking Locc Exit Enter M Main Display Interface F5 Loc Locc M If inputted password is correct Key locking will be valid Exit Enter M Main Display Interface F5 Loc oPEn M If inputted pa...

Страница 33: ...M Main Display Interface F5 Loc PASS Input the new Password Please remember it M If inputted is Operator Password this operation interface will be skipped if inputted is Administrator Password Admini...

Страница 34: ...40005 0 R 03 1 In Peak Value detection process 40005 1 40005 2 40005 3 40005 4 40005 5 40005 6 40005 7 40005 8 40005 9 40005 10 40005 11 40005 12 40005 13 1 Weight is stable 40005 14 1 Overload Alarm...

Страница 35: ...ort 40008 W 06 0xA500 Unused 0xA501 Unused 0xA502 Unused 0xA503 Unused 0xA504 Unused 0xA505 Unused 0xA506 Unused 0xA507 Unused 0xA508 Unused 0xA509 Unused 0xA50A Clear Screen 0xA50B Manual Tare 0xA50C...

Страница 36: ...10 Data Compared with Weight Setpoints UnShort 40026 R W 03 06 0 Gross Weight 1 Net Weight 2 Net Weight Peak Value UnShort 40027 R W 03 06 UnShort 40028 R W 03 06 UnShort 40029 R W 03 06 UnShort 40030...

Страница 37: ...0123 4k DEC Weight Value 7 Bytes 30 39 2EH 0 9 Decimal Point Unit 1 Byte Space k t g 20 6B 74 67 Space None k kg Format B Displayed Characters Byte4 12 d 64 ID Code d Point Code 1 Byte 00 FF BIT7 0 Un...

Страница 38: ...Unit 6B k 13 SUM CC SUM Byte1 Byte2 Byte12 14 END 0D CR 15 END 0A LF Example 2 Sending Displayed Characters 2 dISP Byte Field Name HEX Note 1 START 3D 2 Weighing State 53 S 3 Data Name 44 D 4 ID Code...

Страница 39: ...Technological Co Ltd Address Building A6 Lugu International Industrial Park Changsha 410205 China Tel 86 731 85115100 Fax 86 731 85158100 Website www supmeter com E mail supmeter supmeter com CPC16 0...