Installing the device
21
ATTENTION
Damage to the tubular motor due to forcefully driving into the
winding shaft.
¾
Never drive the tubular motor into the winding shaft using force.
¾
1. Slide the tubular motor with the driver (1) into the winding shaft (2).
¾
2. Slide the winding shaft up to the adapter's limit stop (3) on the driving head
(4).
¾
Make sure that the adapter does not slip from the driving head limit ring.
1
3
4
2.
1.
2
¾
1. Slide the roller capsule (1) up to the limit stop in the winding shaft (2).
¾
2. Place the ball bearing (3) onto the roller capsule axle pin (4).
1
3
4
2.
1.
2
In order to be able to install the device in the roller shutter box, the roller
capsule must first be inserted up to the limit stop into the winding shaft. It
is then pulled out until the device fits precisely into the roller shutter box.
Installing the device in the roller shutter box
¾
Insert the driving head axle pin (1) into the hole in the drive bearing (2).
¾
Make sure that the adjuster screws (3) are accessible.
¾
Make sure that the motor cable (4) is routed downwards.
1
2
3
4
¾
Insert the cotter pin (1) through the securing hole (2) in the axle pin.
1
2
¾
1. Pull the roller capsule (1) out of the winding shaft (2) until the ball bearing (4)
fits into the counter bearing (3).
¾
2. Insert the ball bearing into the counter bearing.
¾
3. Screw the winding shaft down tightly on the roller capsule.
1
1.
3.
2.
3
4
2
¾
Make sure that the winding shaft is installed horizontally.