Chapter 5: Advanced Serverboard Setup
5-25
5-11 SATA Port Connections
SATA Ports
See the table on the right for
pin de
fi
nitions for the onboard
SATA ports.
SATA Port Pin Defi nitions
(I-SATA0 ~ I-SATA5)
Pin # De
fi
nition
1
Ground
2
TXP
3
TXN
4
Ground
5
RXN
6
RXP
7
Ground
Rear UID LED
LED3 is the rear UID LED, located on
the rear of the serverboard. This LED
is used in conjunction with the rear
UID switch to provide easy identi
fi
ca-
tion of a system that might be in need
of service.
UID LED
Status
Color/State OS Status
Blue: On
Windows OS
Unit Identi
fi
ed
Blue:
Blinking
Linux OS
Unit Identi
fi
ed
BMC Heartbeat LED
Status
Color/State De
fi
nition
Green:
Blinking
BMC: Normal
BMC Heartbeat LED
A BMC Heartbeat LED is designated
LED1. When LED1 is blinking, BMC is
functioning normally. See the table at
right for more information.