Chapter 5: Advanced Serverboard Setup
5-23
BMC Enable
Jumper JPB1 allows you to enable the
embedded the Nuvoton WPCM450R
BMC (Baseboard Management) con-
troller to provide IPMI 2.0/KVM support
on the serverboard. See the table on
the right for jumper settings.
BMC Enable
Jumper Settings
Jumper Setting De
fi
nition
Pins 1-2
BMC Enable
Pins 2-3
Normal (Default)
I2C Bus to CPU1/CPU2 VRMs
Use Jumpers JVRM_JI
2
C1/JI
2
C2 to
connect the System Management
Buses (I
2
C) to CPU1/CPU2 VRMs.
The default setting is on pins 1-2 to
Enable the connection. See the ta-
ble on the right for jumper settings.
I
2
C to VRMs
Jumper Settings
Jumper Setting De
fi
nition
Pins 1-2
Enabled (Default)
Pins 2-3
Disabled