SUPERSERVER 6027B-URF User's Manual
3-2
Information LED
This LED will be solid blue when the UID function has been activated. When this
LED
fl
ashes red, it indicates a fan failure. When red continuously it indicates an
overheat condition, which may be caused by cables obstructing the air
fl
ow in the
system or the ambient room temperature being too warm. Check the routing of
the cables and make sure all fans are present and operating normally. You should
also check to make sure that the chassis covers are installed. Finally, verify that
the heatsinks are installed properly (see Chapter 5). This LED will remain
fl
ashing
or on as long as the indicated condition exists.
1
2
3-3 Control Panel LEDs
The control panel located on the front of the chassis has several LEDs. These
LEDs provide you with critical information related to different parts of the system.
This section explains what each LED indicates when illuminated and any corrective
action you may need to take.
NIC1
Indicates network activity on the LAN1 port when
fl
ashing.
NIC2
Indicates network activity on the LAN2 port when
fl
ashing.