Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6017R-TDLF
up and running. Following the steps in the order given should enable you to have
the system operational within a minimal amount of time. This quick setup assumes
that your 6017R-TDLF system has come to you with the processor and memory
preinstalled. If your system is not already fully integrated with a serverboard, proces-
sor, system memory etc., please turn to the chapter or section noted in each step
for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6017R-TDLF was shipped in and note
if it was damaged in any way. If the server itself shows damage, you should fi le a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6017R-
TDLF. It should be situated in a clean, dust-free area that is well ventilated. Avoid
areas where heat, electrical noise and electromagnetic fi elds are generated. You
will also need it placed near a grounded power outlet. Read the Rack and Server
Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6017R-TDLF was shipped in should include two sets of
rail assemblies, rail mounting brackets and the mounting screws you will need to
install the system into the rack. Follow the steps in the order given to complete the
installation process in a minimal amount of time. Please read this section in its en-
tirety before you begin the installation procedure outlined in the sections that follow.
The 6017R-TDLF can also be ordered with the BULK option (6017R-TDLF-BULK).
The box these servers will be shipped in contains 20 servers, 40 heatsinks and
20 sets of rails.
Содержание SUPERSERVER 6017R-TDLF
Страница 1: ...SUPERSERVER 6017R TDLF SUPER USER S MANUAL 1 0...
Страница 5: ...v Preface Notes...
Страница 14: ...1 6 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 20: ...2 6 SUPERSERVER 6017R TDLF User s Manual Figure 2 3 Installing the Outer Rails to the Server Rack 1 2 1 3 1 3...
Страница 26: ...3 4 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 46: ...4 20 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 72: ...5 26 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 82: ...6 10 SUPERSERVER 6017R TDLF Manual Figure 6 7 Removing Replacing the Power Supply...
Страница 114: ...A 2 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 118: ...B 4 SUPERSERVER 6017R TDLF User s Manual Notes...