System Cooling
Two 10-cm blower fans (FAN-0135L4)
System Input Requirements
AC Input Voltage: 100V-240V AC auto-range
Rated Input Current: 4.2A (100V) to 1.8A (240V)
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: 350W (Part# PWS-351-1H)
Rated Output Voltages: +3.3V (15A), +5V (18A), +12V (29A), +5Vsb (3A)
Operating
Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 60º C (-40º to 140º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-Operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic
Emissions:
FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
Electromagnetic
Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety:
EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV
Certifi ed (Germany), CE Marking (Europe)
California Best Management Practices Regulations for Perchlorate Materials:
This Perchlorate warning applies only to products containing CR (Manganese
Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply.
See
www.dtsc.ca.gov/hazardouswaste/perchlorate
”
Содержание SUPERSERVER 6017R-TDLF
Страница 1: ...SUPERSERVER 6017R TDLF SUPER USER S MANUAL 1 0...
Страница 5: ...v Preface Notes...
Страница 14: ...1 6 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 20: ...2 6 SUPERSERVER 6017R TDLF User s Manual Figure 2 3 Installing the Outer Rails to the Server Rack 1 2 1 3 1 3...
Страница 26: ...3 4 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 46: ...4 20 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 72: ...5 26 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 82: ...6 10 SUPERSERVER 6017R TDLF Manual Figure 6 7 Removing Replacing the Power Supply...
Страница 114: ...A 2 SUPERSERVER 6017R TDLF User s Manual Notes...
Страница 118: ...B 4 SUPERSERVER 6017R TDLF User s Manual Notes...